Different Key Macros per session

$
0
0

We are under Wavelink Telnet on Windows CE

 

We have two sessions, one is VT220 and the other is 5250

 

since pressing F5 transmit nothing by default under a VT session, whe've added a Key Macro to generate Esc[15~ (mandatory in my customer's application)

 

the problem is when we switch to the 5250 session and press F5 : the same key macro is generated instead of the expected 5250 F5

 

Is there a possibility to specify in a key macro which session is concerned to avoid this problem ?

 

Thanks


Is there a way to emulate page up and page down for motorola MC3190 ?

$
0
0

Good morning,

is there a possibility to scroll up and down my screen when i'm using a wavelink 5250 emulation ?

 

I can't use any combination of keys or the up/down specific keys.

 

Can someone help me please?

Thanks.

Roberto

Wavelink Terminal Emulation couldn't use scanner in Honeywell Dophin 6110

$
0
0

Wavelink Terminal Emulation (version is 6100_WM6_7_3) couldn't use scanner when pressing scanning key in Honeywell Dophin 6110.

We also have tried disabling the scanner of Wavelink Terminal Emulation (by setting 'Emulation Parameters' - 'Scanner' - 'Common' - 'Disable Scanner' to 'Yes') and using scanwedge, but the scanner also couldn't work.

How to avoid character when decode on TE.

$
0
0

Dear Team,

Currently , we are facing the issue when scan cargo at my warehouse that we can a 1 cargo with a lot of labels and each label will have 1 barcode with 20 numeric not character, but sometimes scanning decode data numeric with wrong data mix some character , ex : AB123868493939533543 , it should be 23123868493939533543.

 

Please help us to check and give solution how to prevent character display when decode.

Thanks in advance.

exit TE

$
0
0

Hi support

How do I exit Wavelink TE on CK3x device

F5 not working in Velocity Browser

$
0
0

Hi Team,

 

Customer is using Panasonic FZ-N1 device for SAP browser base application.

 

After entering username & password in login page of SAP,F5 or enter key not working for logon.

 

Same URL is working on Zebra MC3200 device with enter/F5.

 

I have tried multiple keycode like E03F,3F00,0074 & 3F00:\001B[15~.But nothing is working.

 

Kindly help.

 

 

Regards,

ARUN

barcode scanner on telnetCE, device intermec CN51

$
0
0

Hello

ii worked before on cn70 and telnetce, but now i received new intermec cn51.

Installed:

WLTE_UNI_WM65_LANG_7_3_225_AS.exe

on telnetCE, barcode scanner dont write data, outside TelnetCE screen, works fine

 

changed this parameters but no luck

Emulation Parameters:

    1. Scanner then Common and "Disable Scanner" to YES

    2. Scanner then Common and "Use Scanner As Keyboard Wedge" to ENABLE

 

could you help me?

thanks in advance

lowering ftp timeout in CETerm scripting

$
0
0

Hello Guys,

 

I am using a ftp in CETerm script to send out a text as login. We will send request and after that we logout, without more data exchange. The problem is, when there is a problem with server. it takes a lot of time to find out it can't connect.

 

Is it possible to lower the timeout for the FTP? It takes like 60s to find out that there is a problem, which is a problem.

 

Best Regards

 

Petr


F1 key is not working on Zebra MC32N0

$
0
0

Hi, We are using MC9190 with WL telnet 7.3.146 and all function keys are working fine. Now we are migrating to MC32N0.

 

We exported the config file (.wltna) and imported it into the WL configurator 7.3.303 to keep the same configuration parameters.

 

But now, we figured out that the F1 key is not behaving as in the MC9190. The function expected is to go back to the previous screen/menu, but it is not happening with MC32N0. It looks like the F1 key is not working at all.

 

We tested the key at Program Diagnostics screen and the key code is the same on both PDAs (3B00). Even the regular key is displaying the right key code (letter a = 0061).

 

does anybody know what is causing it?

 

 

Regards.

 

Renato Foresti

Datawedge Cold Boot resistant

$
0
0

Hello,

 

how is it possible to create a package for the motorola Datawedge on devices with oem Version < 3.37 (from this version, the datawedge is preinstalled in the os rom)

that is cold boot resistant, so it can be used after a cold boot again ?

 

Datawedge, e.g. 3.6.16 comes as an *cab file, so the file is automatic deleted after installation.

 

kind regards


Ralf

script to press enter two times, and a script to enter multiple character values.

$
0
0

Velocity users are asking for the functionality of the following:

Script to press enter is already available with Append Hex.

Can this be made to append multiple hex values in consecutive order?

Studio COM's Future

$
0
0

Hello! My software company uses Wavelink Studio COM to create scanner applications and we are concerned that we haven't seen any new releases of the Wavelink Studio COM Server software since 3.7 back in 2003.

 

Can someone shed some light in regards to this product line's future? Is there a new version coming?

How to have loudly sound on MC3190?

$
0
0

Hello,

on MC3190 when we use Telnet CE ( any version) the level of the sound is not enough loud to be hear by a end user in the warehouse

 

we need to know how we can set correctly TelnetCE to have a very heavy sound

 

thanks

 

Sebastien

Is there a way to emulate page up and page down for motorola MC3190 ?

$
0
0

Good morning,

is there a possibility to scroll up and down my screen when i'm using a wavelink 5250 emulation ?

 

I can't use any combination of keys or the up/down specific keys.

 

Can someone help me please?

Thanks.

Roberto

[Motorola WT41N0]How to disable "App launcher" in the Enabler

$
0
0

Hi everyone,

 

I have a probleme with Motorola WT41N0 on Avalanche V6.1

How to disable "App Center" at startup ?

 

In the Enbler, I use the register key "HKLM\SOFTWARE\Microsoft\SVCStart\1\Configurations\Display\@=1" but it changes nothing.

 

Can you help me?

 

Thank you in advance

 

Frédéric

 


Barcode Scan Outputs Special Characters Instead of Numbers

$
0
0

Hello,

 

We have 2 mobile computer scanners that are behaving oddly.  If we make a remote desktop connection to the terminal server of our vendor software, if we scan within that software, the string returned does not match the expected value; it appears to turn some numbers into special characters, and the order of characters has been changed.  In one example, a barcode with string "U558220345" gets output as "5582@)#$U%".  The scan returns normal when I am not inside the remote connection.  I contacted the vendor about this; their rep said that, while they have seen this problem before, the issue is not with their software, but with the configuration of the scanner.

 

I see that the Avalanche has a "Scan Config" menu item, but I'm not familiar with Avalanche at all, and I'm trying to find a way to determine why the barcode data is being "scrambled" as it is.  Any advice would be greatly appreciated.

The taskbar is not visible in TelnetCE, even though I'm not hiding anything in the options tab. How can I get it back, so I cen get into the config menus

$
0
0


I'm using TelnetCE 7.3 with app center.  When I go into TelnetCE, I lose the taskbar which contained the config menus.

So I can't change config or even exit the program.  I'm force to cold boot to exit TelnetCE.  I'm do not have any

options in the 'options' tab checked, so nothing should be hidden.  How can I get it back?

Play beep sound

$
0
0

Hi,

I tried two options to play a beep sound when an error occurs in SAP ITS mobile.

1. BGSOUND

2. IDA_BEEP.

Both did not play the beep sound on the velocity browser on Intermec CK71 RF device. But, both played the sound when I used the internet explorer on Intermec CK71 RF device! 

 

Please let me know if need to use something else to play sound.

 

Code:

IDA_BEEP:

    <script type="text/javascript" language="javascript">

        if (typeof external.CETerm != 'undefined') external.CETerm.PostIDA( "IDA_BEEP", 0 );

    </script>

 

BGSOUND:

<bgsound src="/sap/public/bc/its/mimes/itsmobile/99/sounds/all/sapsounderr.wav" loop="4">

 

Device Details:

RF Device - Intermec CK71

Wavelink Velocity Client - Release 1.0.29 - 07/01/2014

Operating System-Windows Embedded 6.5 Classic. CE OS 5.2.29217 (Build 29217.5.3.12.26)

 

Thanks,

ER

Debugging javascript on velocityCE

$
0
0

Hello,

what is the procedure to debug javascript on web page or log scripting errors to file?

 

We developed a web page, that is working properly in HTML5 browser, but doesn't work on VelocityCE.

 

Rgds,
Frenk

How to hide input panel on Zebra MC9200 CE7.0

$
0
0

Hi,

 

I would like to hide the input panel on a Zebra MC9200 CE7.0 handheld.

 

I did some settings, but the input panel still exists if I click to an input field. The hardware keyboard doesn't work - but this should be active.

 

Does anybody know the correct registry settings?

 