SSL Cert with TelnetCE v7.3.171

$
0
0

I have a Motorola MC3190 running Windows CE v6.0 & TelnetCE v7.3.171. I have successfully loaded the SSL cert onto the device using the steps described here. After launching the TelnetCE program and attempting to initiate a session I get a very generic error. ( Connection to <hostname> SSL/TLS error  [Enter] to Connect ). Pressing [Enter] on the device results in the same error. Any help would be greatly appreciated.

 

Matt


Can't relog back in Telnet session through Connect Pro after AS400 disconnect due to 15 minutes of inactivity.

$
0
0
  • The only way to get devices back in is to restart the Connect Pro services or boot the device manually off the AS400.

 

  • The device is configure to connect to Connect Pro first then failing that, connect to the AS400.

 

  • Here is the extract of the log below.

 

  • There is no re-connect string configured for the Connect Pro or the client.

 

---------------------------------------------------------------------------------------------------------------------------------------

 

// This is the connection to the telnet/ssh host.

hostservice host1

    connect 10.168.0.50:23

    ssh off

    timeout 15m

    undeliverable retain

    reconnect-buffer 5000

 

// The next two lines (if uncommented) allow an AS/400 Workstation ID to be detected.

//  codeset EBCDIC

//  stationid-template "Display[ .]+:\s+(.+?)[ ]"

 

 

// This is the connection to the telnet/ssh client.

proxyservice proxy1

    server host1

    listen 0.0.0.0:4430

    timeout 24h

    nat no

    compression-size 0  // Compression disabled

    compression-level 3

    ssl off

 

 

// This is the web browser interface.

httpserver 10.168.0.130:4428

    ssl off

 

 

// This is how detailed the log file will be.

loglevel Info

 

// This controls the data capturing support.

capture off

    clear off

 

// This controls the automatic restart support.

// restart SU02:00

 

IN 2014-06-10 09:31:59.291 | 10.169.90.3:4802-2030: Requested host service address '10.168.0.50:23' mapped to 'host1'

IN 2014-06-10 09:31:59.291 | 10.169.90.3:4802-2030: Reconnecting to Session ID aba21c893180526eeda26ce0447a21bf

IN 2014-06-10 09:31:59.291 | 10.169.90.3:4801-1994: Dismantling client link 10.169.90.3:4801 to make room for 10.169.90.3:4802-1994

WA 2014-06-10 09:31:59.291 | Ignoring I/O completion error. key: 0x0000000000000CB8, ret: 0, bytes: 0, olap: 0x0000000003EB2540, lastErr: 995

IN 2014-06-10 09:31:59.291 | 10.169.90.3:4802-1994: Host selection ok. Reporting status: Ok (0)

IN 2014-06-10 09:31:59.291 | 10.169.90.3:4802-1994: Reporting Session ID: aba21c893180526eeda26ce0447a21bf

IN 2014-06-10 09:31:59.291 | 10.169.90.3:4802-1994: Reconnected to host1 at 10.168.0.50:23. Local address: 10.168.0.130:37369. HRC: 2

IN 2014-06-10 09:31:59.873 | 10.169.90.3:4802-2030: Deleting session

Windows Server 2012 R2 Support for Avalanche SE?

$
0
0

Hi Everyone -- any sense of when Avalanche SE will be supported on Windows Server 2012 R2?  I've unsuccessfully attempted installing on that OS, but I am able to get it on WS08R2.

 

Thanks,

-Ben

iOS Devices not locating via GPS or Cell Tower

$
0
0

Hi

 

We have deployed to around 20 iOS devices (iPad 4 / iPad Air) (iPhone 5/5s) and non of them seem to locate via GPS or Cell tower (even when location services is turned on)

 

I have installed the Avalance App and enrolled my Android Device (Galaxy S4) which does locate via GPS.

 

Anything i am missing? any basic configuration (i have only enrolled the devices and currently only pushing ActiveSync settings.

v7.3.194 4/30/2014 Wavelink TE for the Datalogic Universal CE6.0 - Falcon X3

$
0
0

Good morning,

 

in this Release the Industrial Brower/WEB don't load a website.

TE want to dowload the website.

Useing IE direct, everything work's fine. And the older Version v7.3.147 everything fine.

 

Any ideas about this?

 

Thanks a lot.

Studio COM's Future

$
0
0

Hello! My software company uses Wavelink Studio COM to create scanner applications and we are concerned that we haven't seen any new releases of the Wavelink Studio COM Server software since 3.7 back in 2003.

 

Can someone shed some light in regards to this product line's future? Is there a new version coming?

Error Unlicensed (2)

$
0
0

When device tries to connect to Agent the error unlicensed message pops up on the Enabler on device.

I have read the document about this subject (Version 2 - 5 Nov 2013)

I verified all the causes/solutions and we don't match wich none

The Avalanche SE version is 5.0.0.278

The Avalanche Enabler version is 4.09-03 (same version for the old or new devices)

Only the fact that only the "old" (bought August 2011) mobile devices get this error

the new one (bought Sept 2012) doesn't have this error

 

Do we have a "Best before date" to update the mobiles ?

thanks to every body for an idea to fix this problem

How to append a F5 key to the scan data

$
0
0

How to append a F5 key to the scan data.


Wvavelink TelnetCE v7.3.164

Emulation : IBM-5251-11

 

please help thank you.


Emulation TelnetCE problem

$
0
0

Hello,

 

I'm setting up a TelnetCE emulation of the AS400 of my company, but I have a problem :

 

My main goal is to have clickable text where I want to. I've read about the syntax in the emulation parameters (like F(number)=*** or [***]) but when I setup the menu like that in the AS400, the TelnetCE interpretor put some "<" and ">" at the beginning and the end of my text, which makes it not clickable.

 

Where does that come from ?

 

Thanks for your answers.

Wavelink TelnetCE 73197 Display Language - UTF8

$
0
0

Hello.

I have Motorola MC3190 and TelnetCE 73197. I need select UTF8 in "Display Language". It is demand for correct display Russian language in the programm. I do not see UTF8 in list "Display Language".

How i do it?

Best regards,

   Andrey.

Scan Handler - Removing specificed string from the start of a Barcode

$
0
0

Hi I'm trying to configure my RF Guns to remove any barcode that starts with "1P" and that starts with an "S".

 

I have the following code written for the removal of the S but it doesn't seem to be working. Can anyone correct my mistake or show me where I'm making the error. Thanks very much!

 

Syntax= A(0){0,S}[SS]

 

Sam

How to take over a Wavelink configuration

$
0
0

Hello, I have some Motorola MC9100 and I'd like to take over the configuration from one device to another device. I heard that I could copy the Termcfg.bin from the application\wavelink folder (via Active Sync) to another MC9100 but that don't work. If I looked in the Termcfg.bin I didn't find my configuration profile.

In which file is the configured profile from my Wavelink Telnet (Version 7.3.40) saved?

 

Another possibiltiy to take over the profile should be the Wavelink TelnetCE Configuration Utility but I can't find a download. Is this software only available for

maintenance agreement?

 

I hope you can help me :-)

Thanky You

 

Olaf

Please vote in our poll about the community upgrade

How to update Server Avalanche IP address?

$
0
0

Hi All,

       We need to move our Avalanche server to a new site so the IP address will be changing.  We have 250+ devices currently pointing at the exising IP address. 

 

Could you please advise how we could migrate from one IP address to another with minimal impact?

 

I have been looking at the "Network Profile tab,  Manage IP Address Pools" - If I specify multiple IP addresses here will the devices use this list to replace the "Server Avalanche IP" in the enabler?

 

Thanks,

Dave

How do I copy my Avalanche software Profiles from one server to another

$
0
0

How do I copy or export an existing software profile from an Avalanche SE test server to our production server.

I am don't want to rebuild the package. Or in which directory can I find the exact AVA file to copy over?


How to send F1 key after each scan VT220 emulation

$
0
0

Hi,

 

I need to send the F1 key after each scan in VT220 emulation, how can I setup the scanHandler ?

 

Thanks

_LOCAL.PRF: setting AgentAddress=fqdn instead ip_addr

$
0
0

Hi,

I have avalanche server version 4.9.0.75.

 

During first contact with tha Avanache server, the PDA receive the file _LOCAL.PRF with the following contens:

================================

# Wavelink property file.

 

AgentAddress=10.203.2.10

e.guid=0131343030383030353031373339

e.device.key=GJIKJLIOIIIKHAIKJOGJIKJLIOIIIKHAIKJOHLIOJLIGEFHPIGJFIGJJIG

================================

How can I have AgentAddress=servername.domain.ext without manual intervention?

 

Thankyou

 

Paolo

Function keys with WT41N0 Telnet CE 7.3.192 VT220 emulation

$
0
0

Hi i'm having difficulties using function keys with Motorola WT41N0 Telnet CE 7.3.192 and VT200 emulation. Random charachtes or error message key not recognized is diplayed if i'm trying to use Function keys (F1; F2 etc.) Any ideas?

Issue with User Management

$
0
0

Hello Everyone,

 

After the upgrade to Avalanche Mobility Center 5.3.1, we're having some issues with User Management.

 

The Issue is, Suppose opened the User Management from the FET Console and closed.

Then if we again try to open, it doesn't open at all. We need to log off and login back to open user management.

 

Also one more issue is when we're trying to add a user to the group in User Management. It revokes back all the changes made. No changes are being saved.

Same issue with in IE too.

 

Please advise

Delay Enabler Auto start

$
0
0

Hi

I have seen the 'delay enabler auto start' document:

http://community.landesk.com/support/docs/DOC-27837http://community.landesk.com/support/docs/DOC-27837

 

I cant seem to get this to work. I am using the

StartupDelay:

[HKEY_LOCAL_MACHINE\Software\Wavelink\Avalanche] "StartupDelay"="dword:1388"

This registry causes a delay by adding setting X number of milliseconds (up to a minute) in AvaInit.exe before launching the Monitor.exe.

 

Is the key value Decimal or Hex??#

 

I need around 30 seconds of delay to try and resolve a problem with Psion WorkaboutPro G3 that starts 'Total Recall' on a cold reset (there is no .PFL Total Recall clone file being used so the utility times out eventually) but this appears to be preventing the enabler from launching and executing a client application.

 

thanks

Steve