Is it possible to send the Wavelink configuration using Soti Mobi control?

$
0
0

On Zebra XT15 with Windows mobile 6.5, can i send the wavelink configuration using Soti Mobi control?


barcode scanner on telnetCE, device intermec CN51

$
0
0

Hello

ii worked before on cn70 and telnetce, but now i received new intermec cn51.

Installed:

WLTE_UNI_WM65_LANG_7_3_225_AS.exe

on telnetCE, barcode scanner dont write data, outside TelnetCE screen, works fine

 

changed this parameters but no luck

Emulation Parameters:

    1. Scanner then Common and "Disable Scanner" to YES

    2. Scanner then Common and "Use Scanner As Keyboard Wedge" to ENABLE

 

could you help me?

thanks in advance

Text Goes Off Screen - Wavelink, Produce Pro

$
0
0

Hey everyone,

 

I've been having this issue with my MC9190s and MC92N0s for awhile now and I still haven't figured it out.

 

Basically we run using Produce Pro and the text seems to be running off the screen. I'm not allowed to take the simple route of just enabling the horizontal scroll.

 

Here's what going on:

 

RawyQPe.jpg

 

 

As you can see, the text cuts off at 2. There is more after this. Look below: (All I did to get it all to display for this picture is take the text down to 11 rather than having it at 13, however its far to small.)

 

 

 

OhiST6Y.jpg

 

 

 

It doesn't just change the login screen, it happens all through the software. It's super hard for them to do their job when this is happening. Any ideas?

Verrouillage Wavelink

$
0
0

Bonjour,

 

Afin d'éviter des modifications sur le paramétrage existant, je souhaiterai savoir s'il est possible de verrouiller  les informations encadrées en rouge sur la photo.Host.jpg

Cela fait plusieurs fois que ces informations sont modifiées (surtout le port) et je voudrais que cela ne se reproduise plus.

 

Merci d'avance pour votre aide.

 

PS : Pour info, j'utilise la version 7.0.84.

Avalanche 6.2 installation - DB Connection failed

$
0
0

Dear all,

I would like to know if anyone has made a new install of Avalanche 6.2?

I've attempted this on my PC (Windows 8.1 SQL Server 2012 existing SQL instance) and also Win server 2012 and SQL server - a new machine with nothing installed on it - just Windows server - on which I installed SQL server 2012 and created new instance.

On both machines, the installation is done, during it, Ava install asks for DB connection credential and server which are on the same machine, creates Avalanche Databases.

When installation finished, it's not possible to launch http console; Enterprise server service is stopped, and eache time we try to start is, it fall dows after few seconds with the following error in the logs (colored red):

 

2017-12-13 16:46:43,366 INFO  LoggingProperties        - Avalanche Server version 6.2.0 - (c) 2013-2017 Ivanti

2017-12-13 16:46:43,368 INFO  LoggingProperties        - log4jAvalancheServer.properties: located in C:\Program Files\Wavelink\Avalanche\conf\main\log4jAvalancheServer.properties

2017-12-13 16:46:43,369 INFO  LoggingProperties        - Logging level set to: DEBUG

2017-12-13 16:46:43,372 INFO  ServerConfigProperties   - ServerConfigProperties initializing

2017-12-13 16:46:43,432 INFO  ServerConfigProperties   - server-config.xml: located in file:/C:/Program%20Files/Wavelink/Avalanche/conf/main/server-config.xml

2017-12-13 16:46:43,440 INFO  SpringContextInitializer - SpringContextInitializer initializing

2017-12-13 16:46:45,733 INFO  SpringContextInitializer - api-factory.xml: located in C:\Program Files\Wavelink\Avalanche/conf/main/api-factory.xml; initialized Wed Dec 13 16:46:43 CET 2017

2017-12-13 16:46:45,734 INFO  InstallationUUID         - InstallationUUID initializing

2017-12-13 16:46:45,734 INFO  InstallationUUID         - installationUUID: [de4fd05c-809e-4069-9005-443215c951b7]

2017-12-13 16:46:45,735 DEBUG AvalancheServer          - Installation UUID initialized

2017-12-13 16:46:45,735 INFO  AvalancheServer          - Starting Avalanche Server...

2017-12-13 16:46:45,735 INFO  AvalancheServer          - Local drives are:

2017-12-13 16:46:45,735 INFO  AvalancheServer          - C:\ D:\ E:\ F:\

2017-12-13 16:46:45,737 INFO  DatabaseProperties       - DatabaseProperties initializing

2017-12-13 16:46:45,737 INFO  DatabaseProperties       - Hibernate Dialect set to: com.wavelink.avalanche.db.dialect.WavelinkeSQLServerDialect

2017-12-13 16:46:45,737 INFO  DatabaseProperties       - Database in use: Avalanche

2017-12-13 16:46:45,738 INFO  DatabaseProperties       - Data Source URL set to: jdbc:sqlserver://NEWSRV2017:1433;databaseName=Avalanche

2017-12-13 16:46:45,787 ERROR DatabaseProperties       - HibernateSequenceCheck: No DB connection

2017-12-13 16:46:45,787 ERROR DatabaseProperties       - setDatabaseProperties() failed.

2017-12-13 16:46:45,787 FATAL AvalancheServer          - Unable to initialize DatabaseProperties.

2017-12-13 16:46:45,787 FATAL AvalancheServer          - Initialization failed when attempting to set property: setDatabaseProperties()

2017-12-13 16:46:45,787 FATAL AvalancheServer          - <<<< Avalanche Server will terminate... >>>>

2017-12-13 16:46:45,788 INFO  AvalancheServer          - <<<< Avalanche Server has terminated >>>>

 

Could somebody tell me what happens here and why is the wizard able to create database and establish db connection and not the enterprise server service?

Thx in advance for your help

Elie

In Telnet CE FN F9 and F7 no funktion

$
0
0

Hello all,

 

we have change from Motorola to Zebra Warkabout pro 4.

We use telnet ce 7.3 and we need the F7 and F9 Button.

If i press the Button, no function with CTRL with blue FN no reaction.

so i have do from a other forum,edit the emulationparameters.i must press the 7 button 1sek to press F7.

it‘s work but it is not the best solution.

i want use the F7 With the blue FN Button,what can i do?

 

thansk for help Andre

How to get details of SSID in Wavelink Console

$
0
0

Hi All,

 

I was just looking for a way to display the SSID (Reported and Assigned SSID) in the console. There are properties like AgentAddress, AppliedProfile, AssignedIP, etc., so is there a similar Property for SSID or is there a way we could get it displayed on the AMC Console under Columns or in Filters?

Advance page in Zebra MC32 in Wavelink Terminal Emulation

$
0
0

Hello.

 

I need to configure some Zebra MC32 devices (Windows CE7) with a page advance key in Wavelink TE.

Can you tell me how I can configure it?

 

Thanks in advance.

Carlos


RS507 bluetooth scanner locking up

$
0
0

I am using a Zebra WT41N0 and a RS507 bluetooth scanner, I am also using a TE applications and an AS400 has the host. The issue that I am having is that the user will be working and moving along just fine, they scan a barcode and then nothing happens, the scanner will not product a beam. When I remove and reinsert the battery I get the start up LED's and then it goes back to doing nothing. The only way to fix it is to have the user log out and then reboot the terminal and pair it again. Also the user will be working and the pairing barcode will pop up for unknown reason and asked to be paired again. I tested it with a fully charged battery and it happened to be. I put the scanner in pick list mode and enabled the low battery warnings but I did not get any warnings about battery getting low. Are there any ideas of what could be happening? Thanks

iPad Air with paired Bluetooth Scanner not recognized by TE Client

$
0
0

I have a client with an iPad Air (MF009LL/A) and Generalscan GS-RT1001BT ring scanner.  They are trying to use the ring scanner with the Bluetooth scanner, but the TE Client (2.0.9.4974)  defaults to the iPad camera.  Other Telnet Clients appear to function correctly with the paired scanner.  Any ideas why and how I can fix it?

Macro to set session switch buttons doesn't work

$
0
0

Hello,

 

I'm working with Motorola MC9190s. Sometimes when they come back from repair, the red/green buttons to switch sessions doesn't work. I've tried setting a key Macro like this:

 

007D:\8200 Green button to Previous Session

007E:\8300 Red button to Next Session

 

This doesn't work unfortunately. I've set the macros in both places.  After downloading to the 9190, I see the macros in termcfg.bin and hostcfg.bin in thier respective locations . These were setup prior to me and looking at the other units, they have no macros set. Could someone shed some light on what other ways these keys could have been set?

function key F6-F9 not work with SAP

$
0
0

We are using Wavelink TE on Moto MC32n0(VT100).

Funciton F1-F5 are working well,but F6-F9 not working.

How to make it work.

1.gif

TelNetCE CE 7.3: Next input field

$
0
0

Hi,

We are using SAP ITS with Wavelink Industrial browser 7.3.  We have programmed to go to next input field when "Enter" key is pressed. The functionality is working in the internet explorer but on the WaveLink industrial browser. The function keys are also not working with the industrial browser.

 

Please let me know if I'm missing any step in this.

 

Thanks

Lin

install Wavelink on MC9090

$
0
0

Hi All,

 

Brand new to this. I have my MC9090 hooked up to my Server via USB in the cradle. I installed Wavelink StudioCOM and when I hit click on Load Client it asks for a Wavelink Client File.  Don't know what that is but am I doing this right and if so where do I get this file?

 

Paul

Is the MOT_MC92N0_CE7 Wavelink Product Configuration still supported?

$
0
0

We have MOT_MC92N0_CE7 Wavelink Product Configuration installed on a PC. It is not communicating via USB. Is there a Windows 10 version? Is the product even still supported?


Can you limit the number of devices a user can enroill with?

$
0
0

We are looking at implementing MDM but our network admins are wanting to put some stipulations on items.

 

One being can we limit the number of devices that a single user can enroll once they have the tiny URL?

also wondering how other companies are using wavelink and certificates?  We want to try and tie in some kind of two factor certificate or wireless settings i am curious how others are handling the devices connecting to their internal networks

Wavelink in MC9090 and MC9060?

$
0
0

Hi,

 

I bought two MC9000, one MC9090 and one MC9060. And I need check or installa on PDAs:

 

Wavelink Emulator Telnet installed. With WEB adapter. with Windows CE 5.0 running WaveLink Telnet CE Version 7.0.x

 

So, please can you help me?

 

Thanks

 

Luis

How to send data from a thrid android app to Velocity

$
0
0

My goal is to send data to  Velocity client. For this reason I am using an intent on my custom Application. the code is the following:

 

 

public void  SendToVelocity(View view)
{  Intent sendIntent = new Intent();  sendIntent.setAction("com.wavelink.intent.action.EMDK.SEND");  sendIntent.addCategory("android.intent.category.DEFAULT");  sendIntent.putExtra(Intent.EXTRA_TEXT, "RFID data");  sendIntent.setType("text/plain");   if (sendIntent.resolveActivity(getPackageManager()) != null) {  startActivity(sendIntent);  }

}

However the above code does not get inside if statement. This means that it can not resolve current intent action.

My questions are:

  1. Is the above (com.wavelink.intent.action.EMDK.SEND) action string valid for calling corresponding Velocity Action? If not what is the corrcet string?
  2. The above method would like to be called on a key press. What script to I need to write in Velocity console in order to call a method of another application?

F5 function key is not working in SAP ITS screens

$
0
0

Hi experts,

 

We are using SAP ITS RF and wavelink browser on intermec CK3x devices. We are having an issue with F5 function key. When F5 is hit, the screen just refreshes and it does not do the intended action. It looks like the key code "F5" is not being recognized by ITS template.

 

In the ITS template, we have maintained the following meta tag for "F5".

<META HTTP-Equiv="OnKeydispatch0x74" content="Javascript:setFKey('5');">

 

The keyboard test gives the following key codes for "F5".

F5 = 3F00 under the keyboard test

F5 = 0074 under the windows keyboard test

 

Am I missing something.?

 

Thanks in advance.

Where can I download Naurtech CETerm 5.7