Post install script not working after forced update

$
0
0

Hi

 

If I action a forced update on a device that already has a support package installed the post install script does not action.

The package simply downloads an XML file to a folder and the post install script overwrites the file with a previously configured version.

Package Type: Support

Package contents: Settings.XML

Install Drive/ Path: C: \SD Card

Post install Script:

[COPY]

 

"\Flash File Store\Settings.xml"="\SD Card\Settings.xml"

overwrite = Yes

 

on the first download the post install script works as expected. On subsequent forced updates it doesn't.

 

Yes - you will be asking why im overwriting a file that has been installed....... for now I need to understand if this is expected behaviour please?

If it is then I can elaborate on the overall objectives that need to be satisfied.

 

thanks in advance for any ideas

 

Steve


WT41N0 suspends random when running Wavelink Telnet

$
0
0

We experience akward problem at our customer that the WT41N0 suddenly suspends when running Wavelink

We have tried different firmwares (1.26.48 , 02.46.02, 03.54.02)  with different wavelink versions (7.3.162, 7.3.215 , 7.3.219) and still it occurs

 

 

I've uploaded a film to youtube
IMG 0647 - YouTube

How to read TID + EPC + RESERVED + USER MEMORY in the same time?

$
0
0

Hi...

 

I'm sorry for to opened in the last days two wrong request, and I removed them, but I studied a lot the problem I have and now I found what I would to ask.

When I use the Wavelink Telnet CE with RFID scan, I noticed that the data read is only the EPC. I tried to change the setup of RFID MEMORY BANK and RFID MEMORY BANK FORMAT using the different options, TID, MEMORY BANK but I found only the TID or MEMORY BANK datas (if I use MEMORY BANK it gives me 8 hex chars + EPC data) but not the union of the two datas.

 

For example I take 4 RFID's labels and checked with the scanner that they have 5 different TIDs (for semplify I think they have 01, 02, 03 values).

Now I create on these labels the EPC datas (for semplify I'll give them the same value for all: AAAA).

 

Now I have 3 labels with TID=01 EPC=AAAA and TID=02 EPC=AAAA and TID=03 EPC=AAAA. If I use the scanner on the Wavelink Telnet CE (a Motorola 3190Z handheld) to scan these RFID labels, it read only one label with EPC=AAAA 'cause all have the same EPC value.

 

If I use the VBRFIDSample6 software in Visual Basic installed on the handheld, it gives me the same result, one record with EPC=AAAA but read 3 times.

If I try to read only the TID, it gives me only 1 TID and not the others (read 3 times) and not the original 01 or 02 or 03 values but another value.

I don't understand if there's a mistake when I write the labels and make the wrong operation overwriting the original TID (I don't know if it's possible and I know isn't possibile) or if there's a setup or a parameter on the scanner Wavelink software to let me to read not only TID, or EPC, or User Memory, or Reserved, but all these datas in the same time.

Remote control (strange behavior)

$
0
0

When we connect RC on Avalanche 6.1 to one of our devices (example picture below : Motorola MC17) the following happens regularly (on about 10 % out of the 300 devices using the exact same configuration) :

 

The first screen says connected, then the following screen opens , then there is no way to take over control of the device or use any of the tabs above.

 

Current setup is this : Avalanche 6.1, Remote Control 4.1.3.002 .

We had this problem also before the upgrade ( Avalance 6.0 , Remote Control 4.1.3.001 )

 

Looking forward to your response.

 

Thanks in advance.

 

Stephan C

 

remote.png

Motorola WT41N0 scanner with new Telnet Emulation version 7.3.153 problem

$
0
0

Dear colleagues,

 

I have problem with new demo Motorola Device Mobile Terminal WT41N0 (Windows CE 7.0)  with new vesion 7.3.153 of Wavelink Telnet emulation.I can not be able to scann when I am in Telnet emulation.The scanner is working in Windows normaly but when I am in Telnet it is just not working proparly.The scanner have scanner lane but it is not giving me any resault of scanning.please if somebody have some idea let me know.

 

Thank you very much.

How to have loudly sound on MC3190?

$
0
0

Hello,

on MC3190 when we use Telnet CE ( any version) the level of the sound is not enough loud to be hear by a end user in the warehouse

 

we need to know how we can set correctly TelnetCE to have a very heavy sound

 

thanks

 

Sebastien

How to set up Linux/Firefox to access Avalanche AvaCfgCE configuration

$
0
0

I have a AVA 6.1 Server. To access the WebConsole is no problem. But if I try to edit the Enabler Configuration Software to edit/change parameters.

I already installed "WINE" to execute Windows executables. What do I need to configure to make my Linux working correctly with the Avalanche Configuring packages?

Here are some Screen-shots:

This is one of the packages I want to edit.

AVA_CFGCE1.png

I open the Java with IcedTea

AVA_CFGCE2.png

Here is the error message I receive.

AVA_CFGCE5.png

Naurtech on a XP machine with a on-screen keyboard in kiosk mode

$
0
0

Hello,

 

Our customer ( old PSA and MSC) MPET now. wants to run Naurtech on VX9 (LXE terminals) with windows XP.

They would like to have a on-screen keyboard in the secured kiosk mode of Naurtech.

Is this possible?

Can we ad the Windows xp or Third-party SIP keyboard?

This is for 250 devices.

 

 

Kind regards,

 

Kevin Matthys


5250 emulator issues with WT41N0 devices

$
0
0

We have purchased several WT41N0 devices in the last 4 months.  It seems like ALL of them are having issues with the telnet client in some way or another.  The user will be in the middle of a telnet session and them emulator suddenly closes.  OR, another issue is the scanner.  The user will be using the emulator and the scanner suddenly quits working.   Exiting and going back into the emulator fixes it. 

 

Has anyone had these troubles and how did you fix?

Wavelink Starting Automatically

$
0
0

Hello

 

We have a Motorola Symbol MC9090 and from some days ago the WaveLink software started to start automatically and I don't know how to return to the Windows Mobile main screen to access the other programs. I tried to restart the machine but it didn't work. Now the only screen it shows is one written: No Host Connection <Enter> to Connect


Follow a screen shot attached to this discussion.

 

Anyone knows how can I get out of this screen?

 

foto.JPG

Avalanche Package Builder 6.0.0.5 and Intermec Mobile Device

$
0
0

Hello ,

I want to build with the Package Builder Wavelink a package and send in the Flash (\ CK_FFS) on the terminal CK31c with Win CE 4.2.

What needs in the Package Builder as (Destination Drive, Destination Folder) are provided so that the packet is transmitted to the CK31c?

I've "APPS" or "C" tried as Destination Drive, but the package is not transmitted!

When I select Destination Drive "Windows", the transmission works on CK31c in the Windows directory.

 

The following information on the CK31:

Hardware Version: CK31CB113M402803

Firmware: 4.02.00.0959 Premium

OS Name: WINCE

OS Version: 4.20

MAC 00-19-88-00-d3-8c

 

Wavelink Avalanche Package Builder 6.0.0.5

Avalanche Premise 6.1 for Windows

 

 

Thank you for your Support!

Scan continuously on Telnet CE 7.3

$
0
0

Hi,

 

An application requires the that a scanner scan beam be activated continuously.

The device is going to be mounted on a stand and users will pass bar codes in front of it.

Does the Terminal Emulation CE 7.3 have a command that places the scan beam into a state of continuous scan mode?

We are using Motorola MC3090 and MC3190 Devices.

 

Thanks,

 

Regards,

need to install cab file to intermec CK3X device

$
0
0

AVA 5.3 SE

intermec CK3X 

OS - 5.2.29217(29217.5.3.12.26) 

fw: 1.61.22.0072


Hi

Need to install customer application to the above Intermec CK3X device.  Customer application is cabbed up but  does not automatically install.

Would anyone be able to suggest method to install this cab automatically on this intermec device?  I was thinking create package(via package builder)  and use the wceload.exe cmd in the post install script.  But, wceload.exe is not visible on the device so not sure if this will work or not.  i do know there is another method with intermec devices where you can copy the cab to the flashfilestore\cabfiles folder and reboot the device.  this installs the cab file successfully.  not sure how to code this in the package builder.  any assistance would be appreciated.

Function keys with WT41N0 Telnet CE 7.3.192 VT220 emulation

$
0
0

Hi i'm having difficulties using function keys with Motorola WT41N0 Telnet CE 7.3.192 and VT200 emulation. Random charachtes or error message key not recognized is diplayed if i'm trying to use Function keys (F1; F2 etc.) Any ideas?

How to change the shortcut icon on avalanche desktop?

$
0
0


Hello,

 

I would like to change the Icons of the shortcuts on the avalanche desktop.

Do you have any idea how to realize this?

 

 

Best regards

Dominic


How do I get the Motorola MC92N0-G Series hand held computers configured to work on my existing wireless network?

$
0
0

Background Information:

 

1.  I have Avalanche Wavelink Manager Console version 3.3.205.

2.  It is running on a Server 2003 R2 service pack 2.

3.  The new computer hand held scanner's OS is Windows CE 5.2.29326.

4.  Model of the hand held is Motorola MC92N0-g series.

5.  Need to get the new units connected to Symbol Spectrum 24 access points.

 

Thanks!

Problems with Scanner="AutoTab" attibute on Motorola MC9190

$
0
0

 

Hello.


I have a few questions regarding VelocityCE.

I’m using Motorola MC9190 with Windows Mobile 6.5 as a test device. Device is configured with default configuration settings.

I have seen some inconsistencies in the VelocityCE (Client v1.0.29, Server v1.1.019).

 

HTML page is very simple just for showing my problem which I had or I’m still having.

 

<html>

<head>

    <title>Title</title>

    <meta http-equiv="Scanner" content="Disable"/>

</head>

<body>

    <input tabindex="2" type='text' Scanner="AutoTab" /><br />

    <input autofocus tabindex="1" type='text' /><br />

    <input tabindex="3" type='text' Scanner="AutoTab"  /><br />

</body>

</html>

 

1. Device was not cold booted for quite some time. On page load second input element was not focused first (problem A). In fact no element was focused when page was loaded. I was able to focus input element by hand or by pressing up or down key on the device. When I pressed the scan button the scanned data was present in the input element. But focus stood on the same element and caret blinked before first character(problem B). If I pressed scan button again the new data overwrote the old content in the input element(problem C). Shutting down the application didn’t help. Problems A, B and C gone away by restarting the test device.

 

2. Second problem is that when page loads the scanner should be disabled (if meta tag, like in the test above, is present). This works ok. But if I focus (active) first or third input element scanner is still disabled. As I understand, only when 1. and 3. input element are focused scanner gets enabled? If I refresh the page, then scanner gets enabled, but stays enabled for all input elements. But is should be enabled only for 1. and 3 input element?

 

3. I have problems with Scanner attribute. When scan is triggered on the element which has Scanner attribute with AutoTab content in it, focus stays on the same input element every time I try to scan. Scanner=”AutoTab” attribute should trigger tab key press event after something is scanned? But on my test device this is not the case. Tab key event is not triggered, therefore focus stays on the same element.

 

For example if I attach (keypress and keydown and other) listeners to the input element and if I scan “46000075” I get two events (I tried different code types too). One is Keydown event with keycode 0 and second event is keypress event with keycode 52 . Scanned data is correct, but focus stays on the same element even with Scanner=”AutoTab” attribute.

 

When I add meta tag

<meta http-equiv="ScannerNavigate" content="Javascript:OnScan('%s','%s','%s');" />

and a callback function, that callback function gets called on scan action. Focused input stays empty, which is correct behavior I assume.

But I’m trying to avoid this kind of solution of filling the input elements and jumping on the next element.

 

I just need the second and third question answered, please.

i have the Intermec CN4 device and i want to install wavelink emulator(demo)on it.Is that possible?i didnt find the CN4 device available for downloads.Please advice.

$
0
0

Goo afternoon,

 

I have the Intermec CN4 device and i want to install wavelink emulator(demo)on it.Is that possible?I didnt find CN4 device available on the Wavelink Emulators downloads.Please advice.

VC70N0 Naurtech Customization

$
0
0

i Dear Support Team,

 

I want to customaze the look /font of the Naurtech, when the device connects to the Naurtech then I got a really small command window with small font in the top left corner. So I would like to expend it to the point where the keyboard starts so when I open the keyboard it wouldn't cover the Naurtech window. (Photo in the Attachment).

 

IMG_6005.JPG

 

Keyboard Customization:

 

Do you know if the Keyboard can be Customized? We would only need F-Keys to navigate trough the Menus.

 

Thanks for your help in advance.

 

Best Regards,

 

Ziga

problem with telnet wavelink FALCON X3 + (keys dont work properly)

$
0
0

Hello. I have the falcon x3   with installed wavelink telnet. It works properly. But i have problem with validating authorization. (For ex.: when it works at the mc9190 i can push F1 or "." key left belowe screen). But with Falcon it does not work. Any ideas?

Встроенное изображение 1

Viewing all 7290 articles
Browse latest View live


Latest Images