Hi all
i need to use DATALOGIC FALCON X3 connected to an As400 via 5250 emulator .. i don't understand how to configure keyboard key (not virtual keyboard) so that i can emulate "ENTER" and "Exit fields" keys tipical for As400
Thanks in advance
Hi all
i need to use DATALOGIC FALCON X3 connected to an As400 via 5250 emulator .. i don't understand how to configure keyboard key (not virtual keyboard) so that i can emulate "ENTER" and "Exit fields" keys tipical for As400
Thanks in advance
Hi Team
After os upgrade vc6090 windows mobile 6.5 the TelnetCE version 7.3.xxx require licence
Can we use license Global or we have to specify Country or Continent?
Hello,
I had a preinstalled TelnetCE license on a Symbol handheld device that was sent off for repair. When we received the device back from repair, the os had been flashed and reinstalled so the pre-installed license is no longer there, and TelnetCE only works in demo mode. Is there a way to correct this issue since the device should still have a valid license for the TelnetCE?
I cannot get this script to run when scanning into the user field in my session.
I have set the scope to the field.
function Beep6()
{
for(var i = 0; i < 6; i++){
Device.beep(200,500,50);
}
}
WLEvent.on("Scan", Beep6());
I need to replace a <GS> (group separator) when I scan a GS1-128 barcode by a "]" character. How can I do that using terminal config from Wavelink Industrial Browser?
Hello everybody,
We are facing some problems, with Honeywell CT50 and Wavelink TE.
1) There isn’t a version for CT50 and the universal emulator for Windows 10 can not be installed on CT50 Windows 10IoT Mobile Enterprise.
2) We have installed a universal emulator for Android that we have downloaded from play store. Has someone experience with SAP ITS Mobile on Android OS?
Best regards,
Daniel
Hi...
I'm sorry for to opened in the last days two wrong request, and I removed them, but I studied a lot the problem I have and now I found what I would to ask.
When I use the Wavelink Telnet CE with RFID scan, I noticed that the data read is only the EPC. I tried to change the setup of RFID MEMORY BANK and RFID MEMORY BANK FORMAT using the different options, TID, MEMORY BANK but I found only the TID or MEMORY BANK datas (if I use MEMORY BANK it gives me 8 hex chars + EPC data) but not the union of the two datas.
For example I take 4 RFID's labels and checked with the scanner that they have 5 different TIDs (for semplify I think they have 01, 02, 03 values).
Now I create on these labels the EPC datas (for semplify I'll give them the same value for all: AAAA).
Now I have 3 labels with TID=01 EPC=AAAA and TID=02 EPC=AAAA and TID=03 EPC=AAAA. If I use the scanner on the Wavelink Telnet CE (a Motorola 3190Z handheld) to scan these RFID labels, it read only one label with EPC=AAAA 'cause all have the same EPC value.
If I use the VBRFIDSample6 software in Visual Basic installed on the handheld, it gives me the same result, one record with EPC=AAAA but read 3 times.
I don't understand if there's a mistake when I write the labels and make the wrong operation overwriting the original TID (I don't know if it's possible and I know isn't possibile) or if there's a setup or a parameter on the scanner Wavelink software to let me to read not only TID, or EPC, or User Memory, or Reserved, but all these datas in the same time.
Hi everyone,
I have a probleme with Motorola WT41N0 on Avalanche V6.1
How to disable "App Center" at startup ?
In the Enbler, I use the register key "HKLM\SOFTWARE\Microsoft\SVCStart\1\Configurations\Display\@=1" but it changes nothing.
Can you help me?
Thank you in advance
Frédéric
Guys, morning!
We'd like to get a way to exit though VB code from Wavelink Corporation Studio Client on MC91/MC92. Currently have an application built onto, but need to open other applications by user exit from Wavelink Corporation Studio Client instead of interactive (menu) close.
Do you have a way to code based exit from Wavelink? CurrentVersion is 5.4.1.26
Thanks in advance!
Hello
ii worked before on cn70 and telnetce, but now i received new intermec cn51.
Installed:
WLTE_UNI_WM65_LANG_7_3_225_AS.exe
on telnetCE, barcode scanner dont write data, outside TelnetCE screen, works fine
changed this parameters but no luck
Emulation Parameters:
1. Scanner then Common and "Disable Scanner" to YES
2. Scanner then Common and "Use Scanner As Keyboard Wedge" to ENABLE
could you help me?
thanks in advance
Anyone know how I can do this? When I Start TelnetCE a windows comes up
"Scanner Selection" Do you want to use the scanner "Bluetooth SSI Scanner Driver" instead of the Default scanner "External SSI"
I have to hit no to continue with the connection Profile.
Running TelnetCE version 7.3.158
Thanks,
Hello, I try to activate a license TelnetCE on Motoral device via Lisence Server.
My steps:
1. I installed Licence Server on computer and then I added licences.
2. I installed a client on Motorola device with license server settings as :146.212.32.15:1820
3. When I launch a terminal, it stucks in atteption to connect server.
The version 7.3 matched for both: server lisence and version of client.
In log file I see connection log:
+06155066 2: No "TelnetCE 7.3 IBMHOST" licenses available for MAC Address 0023685F9E6B, Site ID 831
+06155066 2: No "TelnetCE 7.3 IBMHOST" licenses available for MAC Address 0023685F9E6B, Site ID 0
+06155066 2: No "TelnetCE 7.3 VT/IBMHOST" licenses available for MAC Address 0023685F9E6B, Site ID 831
+06155066 2: No "TelnetCE 7.3 VT/IBMHOST" licenses available for MAC Address 0023685F9E6B, Site ID 0
+06155066 2: No "TelnetCE 7.3 VT/IBMHOST/WEB" licenses available for MAC Address 0023685F9E6B, Site ID 831
+06155066 2: No "TelnetCE 7.3 VT/IBMHOST/WEB" licenses available for MAC Address 0023685F9E6B, Site ID 0
+06155066 2: No "TelnetCE Maintenance" licenses available for MAC Address 0023685F9E6B, Site ID 831
+06155066 2: No "TelnetCE Maintenance" licenses available for MAC Address 0023685F9E6B, Site ID 0
It means, the terminal can connect to server.
Status list:
What does unlicensed devices mean? Those devices can not get a license.
Hi@all!
What is to do when we want to move AvalancheMC to another server?
Old server has Server 2003 installed, we have to move to Server 2012.
New server has another IP adress.
Got a valid backup, but not sure if all that we need to restore on a new server is in there.
Hello,
We have 2 mobile computer scanners that are behaving oddly. If we make a remote desktop connection to the terminal server of our vendor software, if we scan within that software, the string returned does not match the expected value; it appears to turn some numbers into special characters, and the order of characters has been changed. In one example, a barcode with string "U558220345" gets output as "5582@)#$U%". The scan returns normal when I am not inside the remote connection. I contacted the vendor about this; their rep said that, while they have seen this problem before, the issue is not with their software, but with the configuration of the scanner.
I see that the Avalanche has a "Scan Config" menu item, but I'm not familiar with Avalanche at all, and I'm trying to find a way to determine why the barcode data is being "scrambled" as it is. Any advice would be greatly appreciated.
Hi,
I tried two options to play a beep sound when an error occurs in SAP ITS mobile.
1. BGSOUND
2. IDA_BEEP.
Both did not play the beep sound on the velocity browser on Intermec CK71 RF device. But, both played the sound when I used the internet explorer on Intermec CK71 RF device!
Please let me know if need to use something else to play sound.
Code:
IDA_BEEP:
<script type="text/javascript" language="javascript">
if (typeof external.CETerm != 'undefined') external.CETerm.PostIDA( "IDA_BEEP", 0 );
</script>
BGSOUND:
<bgsound src="/sap/public/bc/its/mimes/itsmobile/99/sounds/all/sapsounderr.wav" loop="4">
Device Details:
RF Device - Intermec CK71
Wavelink Velocity Client - Release 1.0.29 - 07/01/2014
Operating System-Windows Embedded 6.5 Classic. CE OS 5.2.29217 (Build 29217.5.3.12.26)
Thanks,
ER
Hello,
how is it possible to create a package for the motorola Datawedge on devices with oem Version < 3.37 (from this version, the datawedge is preinstalled in the os rom)
that is cold boot resistant, so it can be used after a cold boot again ?
Datawedge, e.g. 3.6.16 comes as an *cab file, so the file is automatic deleted after installation.
kind regards
Ralf
Hello, I have some Motorola MC9100 and I'd like to take over the configuration from one device to another device. I heard that I could copy the Termcfg.bin from the application\wavelink folder (via Active Sync) to another MC9100 but that don't work. If I looked in the Termcfg.bin I didn't find my configuration profile.
In which file is the configured profile from my Wavelink Telnet (Version 7.3.40) saved?
Another possibiltiy to take over the profile should be the Wavelink TelnetCE Configuration Utility but I can't find a download. Is this software only available for
maintenance agreement?
I hope you can help me :-)
Thanky You
Olaf
I'm using a Datalogic Skorpio X3 and I have a web page in html5 and with Velocity I only see an icon and with other browsers the information appears.If I refresh the page the Velocity stop responding.
Rui
how do i install a wavelink licence onto a scanner?