How to hide input panel on Zebra MC9200 CE7.0

$
0
0

Hi,

 

I would like to hide the input panel on a Zebra MC9200 CE7.0 handheld.

 

I did some settings, but the input panel still exists if I click to an input field. The hardware keyboard doesn't work - but this should be active.

 

Does anybody know the correct registry settings?

 

BR

Jürgen


IPAD Pro mit Bluetooth Tastatur Entertaste funktioniert nicht

$
0
0

Guten Morgen zusammen,

 

ich hätte eine Frage bezüglich einer Entertaste in der Wavelink TE for iOS App. Beim eintragen der Login Daten in die AS400, ist die Enter Taste ohne funktion und nach dem Drücken der Taste springt das Eingabefeld immer nur ein Feld nach unten.

Die Einstellung (Enter Taste umkehren damit die Bestätigung funktioniert.) habe ich eingestellt aber leider ohne erfolg. Gibt es da noch andere möglichkeiten die Entertaste zu programmieren ?

 

Vielen Dank schon mal und schöne Grüße

 

Daniel Kortas

Motorola MC9190: enabler splash screen displayed for long time if task bar auto hide is setting

$
0
0

-Device Motorola MC9190G
-Enabler version 5.3.59
Description:
At system boot, task bar is setting "auto hide" via AutoHide.reg file located in \Application directory.
the file content is:
REGEDIT4

[HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Shell\AutoHide]
@=dword:00000001

With this setting, the enabler splash screen is shown for 100 sec.
Without auto hide setting, the enabler splash screen is shown for 10 sec.


Any suggestions?


Thank you

Paolo

Zebra Motorola MC9200 Windows Embedded Compact 7 Volume Power cold boot resistant

$
0
0

Got today the new MC9200.

Speaker ist terrible loud, so i set via control Panel the volume to Soft. After cold boot, the Sound ist set again to Default.

 

How can i prevent this. Windows Embedded Compact is new to us.

 

Thx

 

Ralf

How to give a field Exit at a specific field?

$
0
0

I got the request form our users that they want to use as little buttons as possible as they are scanning. We have a screen where there are two barcode fields that need to be scanned. Now the scanner is configured that it is able to scan a code, give a field exit and then scan another barcode and give another field exit. Then it needs to display information that corresponds with those two bar-codes but right now they have to press Enter (which has the field exit command under it) to get that information displayed. Is it possible to configure it as such that if that field is selected it automatically gives another field exit? Or perhaps that that specific field is given a field exit after the two fields are filled so that the information is displayed.

The taskbar is not visible in TelnetCE, even though I'm not hiding anything in the options tab. How can I get it back, so I cen get into the config menus

$
0
0


I'm using TelnetCE 7.3 with app center.  When I go into TelnetCE, I lose the taskbar which contained the config menus.

So I can't change config or even exit the program.  I'm force to cold boot to exit TelnetCE.  I'm do not have any

options in the 'options' tab checked, so nothing should be hidden.  How can I get it back?

Barcode Scan Outputs Special Characters Instead of Numbers

$
0
0

Hello,

 

We have 2 mobile computer scanners that are behaving oddly.  If we make a remote desktop connection to the terminal server of our vendor software, if we scan within that software, the string returned does not match the expected value; it appears to turn some numbers into special characters, and the order of characters has been changed.  In one example, a barcode with string "U558220345" gets output as "5582@)#$U%".  The scan returns normal when I am not inside the remote connection.  I contacted the vendor about this; their rep said that, while they have seen this problem before, the issue is not with their software, but with the configuration of the scanner.

 

I see that the Avalanche has a "Scan Config" menu item, but I'm not familiar with Avalanche at all, and I'm trying to find a way to determine why the barcode data is being "scrambled" as it is.  Any advice would be greatly appreciated.

Problem with VT100 session - function key

$
0
0

In VT100 session you must press the ENTER key after a function key.  it's possible automatically send the ENTER key after a function key?

My device is a WinCE MC9200 handheld Mobile Computer.

 

Thanks.


key ROLL UP/DW

$
0
0

using Telnet Wavelink rel. 7.3.247 on the MC92N0 5250, pressing the Ctrl + J / L keys, the ROLL UP / DW function will not work.

where am I wrong?

thanks in advance.

Rino

How I replace GS (Group Separator) from GS1-128 by "]" character ?

$
0
0

I need to replace a <GS> (group separator) when I scan a GS1-128 barcode by a "]" character. How can I do that using terminal config from Wavelink Industrial Browser?

Honeywell Dolphin 70e Mapping Function Key's

$
0
0

I am having trouble mapping the function key's for this unit.

 

Function 1

Function 2

Function 3

Function 4

ESC

ENTER

 

Any ideas on how to do this?

Scan Handler (Enter after barcode scan) not working

$
0
0

Hello,

 

I'm having problems with a Motorla scanner and Wavelink.

Everything (i need) that is configured in Emulation Parameters works, but the only thing that does not work is a "return" on barcode scan (Scan Handler).

My Wavelink version is TelnetCE 7.2.00 and i have a licence for VTHP.

 

29-1-2015 12-08-22.jpg

 

I have also tried to use A(0)[A\\0D] but that does not work either.

 

29-1-2015 12-43-29.jpg

The manual found on this page does not help either:

https://community.landesk.com/support/docs/29959

 

Is this a Wavelink version problem? Or am i doing something else wrong?

 

Scan Terminator is also \0D:

 

29-1-2015 12-46-31.jpg

 

I have re-installed the Wavelink software on the Scanner, but that didn't help either.

 

Does anyone have any idea that i'm doing wrong?

 

The scanner is a Motorola MC9090 with WIndows Mobile 5.1

 

Thanks in advance!

 

Greetings,

 

Zarko

WinPC enabler silent installer

$
0
0

Is there a way to automatically install the Wavelink Enabler for WIndows pc without have to press the next buttons?

 

I want to write a script to configure a touchscreen pc with Windows XP embedded, so it's accessible remotly with avalanche. So far i'm not able to automate the installation process of the wavelink enabler.

 

I tried command options like -nogui /nogui but the installer always opens an installation window.

 

Are there options to automate the installation process. I'm currently using version 5.3.33

The taskbar is not visible in TelnetCE, even though I'm not hiding anything in the options tab. How can I get it back, so I cen get into the config menus

$
0
0


I'm using TelnetCE 7.3 with app center.  When I go into TelnetCE, I lose the taskbar which contained the config menus.

So I can't change config or even exit the program.  I'm force to cold boot to exit TelnetCE.  I'm do not have any

options in the 'options' tab checked, so nothing should be hidden.  How can I get it back?

need to install cab file to intermec CK3X device

$
0
0

AVA 5.3 SE

intermec CK3X 

OS - 5.2.29217(29217.5.3.12.26) 

fw: 1.61.22.0072


Hi

Need to install customer application to the above Intermec CK3X device.  Customer application is cabbed up but  does not automatically install.

Would anyone be able to suggest method to install this cab automatically on this intermec device?  I was thinking create package(via package builder)  and use the wceload.exe cmd in the post install script.  But, wceload.exe is not visible on the device so not sure if this will work or not.  i do know there is another method with intermec devices where you can copy the cab to the flashfilestore\cabfiles folder and reboot the device.  this installs the cab file successfully.  not sure how to code this in the package builder.  any assistance would be appreciated.


Telnet emulator session block

$
0
0

Hello,

 

Our warehouse logistics are handled through an internal ERP application ensuring a proper flow of the reception and distribution of auto parts.

For this purpose we use around 110 mobile terminals with barcode scanners (RF Guns) of which 50 are deployed in the central warehouse.

 

The models used are:

Motorola MC2100

Datalogic Falcon X3

Datalogic Skorpio

 

In the central warehouse we are currently using 50 Motorola MC2100 scanners with Windows CE 6.0 operating system. As an emulator we are using Wavelink Corporation’s Telnet version 7.3.63 for Motorola MC2100 terminals.

Lately, the following problem began to manifest itself:

On a daily basis every Motorola MC2100 device suffers one or more unexplainable telnet session blocks.

When this happens, the terminal cannot interact with the application any more, the keyboard stops working and after a few minutes the display shows the "disconnected session" message. The terminal’s log doesn’t record any loss of connection to the access point.

The Access Points are all newly acquired from Motorola in order to ensure maximum compatibility between them and the mobile terminals.

 

Our question is:

To what extent the Telnet emulator may influence these session blocks, taking into account the following:

1. Telnet version

2. Certain parameters of the telnet configuration

3. “Avalanche Enable” configuration – we are using the Avalanche platform version 5.3.0.572 to manage our terminals

4. Having a large number of sessions (high load) on an Access Point.

 

Can you please help us with any idea in tackling this problem? Is there a log monitoring tool that can help us to identify the cause of these problems?

The situation is very critical and this seriously influences the process of delivery and reception of goods.

 

Thank you,

 

Florian Baloi

FlorianBaloi@augsburg.ro

TLS 1.2 support in Velocity?

$
0
0

Questions:

Does Velocity support TLS 1.2 protocol?  I am pretty sure this is yes.

  Does it support importing TLS certificates?

Customize Audio/Beep for 5250 Emulation error

$
0
0

Hi all

 

i would like to know if is it possibile to set  a particular tone (different from barcode read or type in keyborad)  when the system (Ibm i -As400 in this case)  write a 5250 screen with MSGALARM activated

Thanks in advance

 

P.S. my need is to inform the user via audio/beep that shoud check the error in the display correct the error

SSH support not working after cold boot

$
0
0

We have a Motorola MC9190 with Wavelink installed and I have installed the SSH support for it but after every cold boot I lose the option for SSH. Anyone know who to make this stick after a cold boot?

Web console is not working after Apache Tomcat 7.0.42 patch

$
0
0

I am running AvalancheMC v 5.3.1.  I receive the following error when using the web console at http://{servername}:8080/AvalancheWeb/login.jsf:

 

HTTP Status 404 - /AvalancheWeb/login.jsf


type Status report

message/AvalancheWeb/login.jsf

descriptionThe requested resource is not available.


Apache Tomcat/7.0.42

 

This was working correctly before the patch. Any suggestions?

Viewing all 7290 articles
Browse latest View live


Latest Images

<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>