Wavelink Licenseserver spamming other servers on port 1820 and 2001

$
0
0

Hello,

 

in the security eventlog. It is Windows Filterring Platform that blocks a packet from 2 servers on which Wavelink Licenserver is installed. The event happens every 2. Minut.

 

IP: 10.XXX.XXX.165/166 (IPs of Wavelink servers) port 2001 and port 1820. If I look at these 2 ports, they are used by “LicenseServer.exe”. It Is startet by the “Wavelink Client License Server” service.

 

pic1.png

 

I can read from the configuration file that Port 1820 is used for contact to other licenseserver. (I have created a DNS entry for both servers)

So it could be possible that Wavelink is pulling other servers than the one specified in the configuration file for a license?

 

Example on one server. In 2 days there are 96.877 security event. 38.082 of them are event ID 5152, and almost all of the are Autir Failure events from the Wavelink Client License Server service, installed the 2 servers above.

 

pic2.png

 

 

 

Here is the configuration file, maybe something should be set up different?

######################################
#  License Server Configuration File
######################################


LicenseAddress = 0.0.0.0:1820


HttpAddress = 0.0.0.0:4420


Username = "XXX"
Password = "YYY"

 


# "OtherServer" lines allow you to specify the addresses of other additional license servers.
# These servers can then be kept synchronized if they have the same username and password specified.
# You can use multiple OtherServer lines if you have multiple license servers besides this one.
# Use the format "OtherServer = address:port" for each line.
# If the port value is not specified, port 1820 is assumed.
#
# The License Server will always try to detect other servers on the same network section.
# This option is only needed to detect servers on other sections of the network.

#OtherServer = corporateserver7:1820
OtherServer = wavelink02


ServerSiteId = 0


ShowAllLicenses = TRUE


SiteIdForUnassignedDevices = 0


ReassignDays = 14


LogLevel = INFO


LogSize = 1000000


LogBackups = 3

 

 

---------------------------------------------

Here are some entries from the Wavelink log on one of the servers. Dosnt look right to me. Can you tell me what this error means?

 

+142378125 2: No "TelnetCE Maintenance" licenses available for MAC Address 002368D60AFE, Site ID 0

+142383375 2: No "TelnetCE 7.0 VT" licenses available for MAC Address 002368D57C93, Site ID 0

+142383375 2: No "TelnetCE 7.0 VT/IBMHOST" licenses available for MAC Address 002368D57C93, Site ID 0

+142383375 2: No "TelnetCE 7.0 VT/IBMHOST/WEB" licenses available for MAC Address 002368D57C93, Site ID 0

+142383375 2: No "TelnetCE Maintenance" licenses available for MAC Address 002368D57C93, Site ID 0

+142383407 2: No "TelnetCE 7.0 VT" licenses available for MAC Address 002368D60AFE, Site ID 0

+142383407 2: No "TelnetCE 7.0 VT/IBMHOST" licenses available for MAC Address 002368D60AFE, Site ID 0

+142383407 2: No "TelnetCE 7.0 VT/IBMHOST/WEB" licenses available for MAC Address 002368D60AFE, Site ID 0

+142383407 2: No "TelnetCE Maintenance" licenses available for MAC Address 002368D60AFE, Site ID 0

+142388625 2: No "TelnetCE 7.0 VT" licenses available for MAC Address 002368D57C93, Site ID 0

+142388625 2: No "TelnetCE 7.0 VT/IBMHOST" licenses available for MAC Address 002368D57C93, Site ID 0

+142388625 2: No "TelnetCE 7.0 VT/IBMHOST/WEB" licenses available for MAC Address 002368D57C93, Site ID 0

+142388641 2: No "TelnetCE Maintenance" licenses available for MAC Address 002368D57C93, Site ID 0

+142388672 2: No "TelnetCE 7.0 VT" licenses available for MAC Address 002368D60AFE, Site ID 0

+142388672 2: No "TelnetCE 7.0 VT/IBMHOST" licenses available for MAC Address 002368D60AFE, Site ID 0

 

Any help appriciated. Thank you

 


F5 function key is not working in SAP ITS screens

$
0
0

Hi experts,

 

We are using SAP ITS RF and wavelink browser on intermec CK3x devices. We are having an issue with F5 function key. When F5 is hit, the screen just refreshes and it does not do the intended action. It looks like the key code "F5" is not being recognized by ITS template.

 

In the ITS template, we have maintained the following meta tag for "F5".

<META HTTP-Equiv="OnKeydispatch0x74" content="Javascript:setFKey('5');">

 

The keyboard test gives the following key codes for "F5".

F5 = 3F00 under the keyboard test

F5 = 0074 under the windows keyboard test

 

Am I missing something.?

 

Thanks in advance.

Waveklink browser: Buttons are misplacing from screen to screen

$
0
0

Hi All

While processing the SAP transactions in wavelink browser (MC92N0), the screen elements (push buttons) are misplacing when moving from one transaction/screen to another transaction/screen.

How to prevent this, please advice we are in a final crunch.

Appreciate your quick response.

 

Incorrect Screen with misplaced buttons

 

Correct Screen:

Delayed key respose motorola VH10

$
0
0

Hello,

 

Has anybody encountered the problem where on initial load of Wavelink Industrial browser on Windows CE 6.00 running on Motorola VH10 device everything is fine but after a while of operating the key presses are very delayed ? It takes a few seconds for a key press to register?

 

Thanks,

Installing Avalanche 5.3 windows 10 fall creator update

$
0
0

Hi, 

 

Does anyone have any experience with Avalanche 5.3 installing on an MC9190 running windows ce using windows 10 Fall Creator update?

 

We can't seem to figure this out and Zebra doesn't seem to know what has broke after the fall creator update.

 

A VC6090 running windows mobile works fine.  I did get this working once.  But after a reboot the MC9190 doesn't even show up in device manager when I place it in the cradle. 

 

Any thoughts would be great.

 

Thanks.

Does anyone have a script to disable scanning on the WT41N0?

$
0
0

I would like to disable scanning while the microphone is inactive.

How to Use DataWedge on Intermec CK71

$
0
0

I pushed a package to install DataWedge on a CK71 device but am not able to run DataWedge (it remains in Idle mode). What am I missing? The scanner port is enabled and I have tried turning scanwedge on/off.

install Wavelink on MC9090

$
0
0

Hi All,

 

Brand new to this. I have my MC9090 hooked up to my Server via USB in the cradle. I installed Wavelink StudioCOM and when I hit click on Load Client it asks for a Wavelink Client File.  Don't know what that is but am I doing this right and if so where do I get this file?

 

Paul


Selection criteria is not working.

$
0
0

Hi guys! i have just installed on my virtual machine the new Avalanche version (Avalanche 6.1 SP3 (6.1.106.496) release) and im having problems whit selection criteria.

 

The devices all the time stays in Unassigned Devices , ignoring all my folders and the selection criteria.

 

Tips:

 

1- The devices are licensed

2- The Mobile devices server are correctly established in their regions and running.

3- I tried to reinstall the Mobile Device server whit no result.

4- Everything is deployed , and the devices are contacting whit the server.

5- The selection criteria i usually use : ModelName , TerminalID, or IP. The selection criteria wizzard show has valid.

 

 

Switch between Telnet VT sessions too long CV31 7.3.296.

$
0
0

Hi
The switch between sessions, is very long on a CV31 Ce7.0. Version TE 7.3.296. I clocked, and it's over 30 seconds each time. Despite the disabling of network support, the problem remains unresolved. An idea ?
CV31 + SR61B + Wavelink TelnetCE 7.3.256- 4 VT sessions.

PS: I tried the universal version, and no problem switch but problems reading Bluetooth SR61B scanner.

see the video real time attached.

Thanks fo Help

RS507 bluetooth scanner locking up

$
0
0

I am using a Zebra WT41N0 and a RS507 bluetooth scanner, I am also using a TE applications and an AS400 has the host. The issue that I am having is that the user will be working and moving along just fine, they scan a barcode and then nothing happens, the scanner will not product a beam. When I remove and reinsert the battery I get the start up LED's and then it goes back to doing nothing. The only way to fix it is to have the user log out and then reboot the terminal and pair it again. Also the user will be working and the pairing barcode will pop up for unknown reason and asked to be paired again. I tested it with a fully charged battery and it happened to be. I put the scanner in pick list mode and enabled the low battery warnings but I did not get any warnings about battery getting low. Are there any ideas of what could be happening? Thanks

What program can be used to load the browser from Windows 10

$
0
0

What program can be used to load the WaveLink Telnet CE Web browser from a Windows 10 PC?  I have been using Windows Mobile Device Center from Windows 7 pc's but it is not supported on Windows 10.

function key F6-F9 not work with SAP

$
0
0

We are using Wavelink TE on Moto MC32n0(VT100).

Funciton F1-F5 are working well,but F6-F9 not working.

How to make it work.

1.gif

Is it possible to send the Wavelink configuration using Soti Mobi control?

$
0
0

On Zebra XT15 with Windows mobile 6.5, can i send the wavelink configuration using Soti Mobi control?

Where can I download Naurtech CETerm 5.7


Macro to set session switch buttons doesn't work

$
0
0

Hello,

 

I'm working with Motorola MC9190s. Sometimes when they come back from repair, the red/green buttons to switch sessions doesn't work. I've tried setting a key Macro like this:

 

007D:\8200 Green button to Previous Session

007E:\8300 Red button to Next Session

 

This doesn't work unfortunately. I've set the macros in both places.  After downloading to the 9190, I see the macros in termcfg.bin and hostcfg.bin in thier respective locations . These were setup prior to me and looking at the other units, they have no macros set. Could someone shed some light on what other ways these keys could have been set?

Can you limit the number of devices a user can enroill with?

$
0
0

We are looking at implementing MDM but our network admins are wanting to put some stipulations on items.

 

One being can we limit the number of devices that a single user can enroll once they have the tiny URL?

also wondering how other companies are using wavelink and certificates?  We want to try and tie in some kind of two factor certificate or wireless settings i am curious how others are handling the devices connecting to their internal networks

Display Device Name of MC55 in Wavelink?

$
0
0

Hello community,

 

it is possible the device name display in Wavelink?

 

As our warehousemen are always asked about the device name and they are not allowed from the application, it is difficult to determine the.

 

Is there a solution for this?

How to send data from a thrid android app to Velocity

$
0
0

My goal is to send data to  Velocity client. For this reason I am using an intent on my custom Application. the code is the following:

 

 

public void  SendToVelocity(View view)
{  Intent sendIntent = new Intent();  sendIntent.setAction("com.wavelink.intent.action.EMDK.SEND");  sendIntent.addCategory("android.intent.category.DEFAULT");  sendIntent.putExtra(Intent.EXTRA_TEXT, "RFID data");  sendIntent.setType("text/plain");   if (sendIntent.resolveActivity(getPackageManager()) != null) {  startActivity(sendIntent);  }

}

However the above code does not get inside if statement. This means that it can not resolve current intent action.

My questions are:

  1. Is the above (com.wavelink.intent.action.EMDK.SEND) action string valid for calling corresponding Velocity Action? If not what is the corrcet string?
  2. The above method would like to be called on a key press. What script to I need to write in Velocity console in order to call a method of another application?

Velocity TE - how to map keys for MC92N0 / keys not working.

$
0
0

We need to remap some keys for the MC92N0 to match application functionality in a TE / VT220 emulator.  I see that there is a ReplaceKey script in the LIbrary as an example, but it doesn't seem to work even when I hard code keyscan values.  Is there a different/easier way?