Velocity Android Keyboard

$
0
0

is it possible to have a keyboard only on the Right\left side of the display in a landscape Mode?

I was able to generate a keyboard, by the console, but not able to find any information about the position  (X,Y) of it on the display.

The keyboard is always showed on the bottom of the display and for all length of the display.


How to send data from a thrid android app to Velocity

$
0
0

My goal is to send data to  Velocity client. For this reason I am using an intent on my custom Application. the code is the following:

 

 

public void  SendToVelocity(View view)
{  Intent sendIntent = new Intent();  sendIntent.setAction("com.wavelink.intent.action.EMDK.SEND");  sendIntent.addCategory("android.intent.category.DEFAULT");  sendIntent.putExtra(Intent.EXTRA_TEXT, "RFID data");  sendIntent.setType("text/plain");   if (sendIntent.resolveActivity(getPackageManager()) != null) {  startActivity(sendIntent);  }

}

However the above code does not get inside if statement. This means that it can not resolve current intent action.

My questions are:

  1. Is the above (com.wavelink.intent.action.EMDK.SEND) action string valid for calling corresponding Velocity Action? If not what is the corrcet string?
  2. The above method would like to be called on a key press. What script to I need to write in Velocity console in order to call a method of another application?

Can you limit the number of devices a user can enroill with?

$
0
0

We are looking at implementing MDM but our network admins are wanting to put some stipulations on items.

 

One being can we limit the number of devices that a single user can enroll once they have the tiny URL?

also wondering how other companies are using wavelink and certificates?  We want to try and tie in some kind of two factor certificate or wireless settings i am curious how others are handling the devices connecting to their internal networks

Default text size on Telnet CE

$
0
0

How can i set default text size to smaller on start?

Where can I download Naurtech CETerm 5.7

How to get details of SSID in Wavelink Console

$
0
0

Hi All,

 

I was just looking for a way to display the SSID (Reported and Assigned SSID) in the console. There are properties like AgentAddress, AppliedProfile, AssignedIP, etc., so is there a similar Property for SSID or is there a way we could get it displayed on the AMC Console under Columns or in Filters?

Delayed key respose motorola VH10

$
0
0

Hello,

 

Has anybody encountered the problem where on initial load of Wavelink Industrial browser on Windows CE 6.00 running on Motorola VH10 device everything is fine but after a while of operating the key presses are very delayed ? It takes a few seconds for a key press to register?

 

Thanks,

I have successfully downloaded .reg file to the correct location on an MC45 Motorola Scanner, but I want to automatically run/regmerge the file what Avalanche command do I use

$
0
0

I want to run a .reg file automatically via Avalanche script, can someone post the syntax for this please


How to send data from a thrid android app to Velocity

$
0
0

My goal is to send data to  Velocity client. For this reason I am using an intent on my custom Application. the code is the following:

 

 

public void  SendToVelocity(View view)
{  Intent sendIntent = new Intent();  sendIntent.setAction("com.wavelink.intent.action.EMDK.SEND");  sendIntent.addCategory("android.intent.category.DEFAULT");  sendIntent.putExtra(Intent.EXTRA_TEXT, "RFID data");  sendIntent.setType("text/plain");   if (sendIntent.resolveActivity(getPackageManager()) != null) {  startActivity(sendIntent);  }

}

However the above code does not get inside if statement. This means that it can not resolve current intent action.

My questions are:

  1. Is the above (com.wavelink.intent.action.EMDK.SEND) action string valid for calling corresponding Velocity Action? If not what is the corrcet string?
  2. The above method would like to be called on a key press. What script to I need to write in Velocity console in order to call a method of another application?

RS507 bluetooth scanner locking up

$
0
0

I am using a Zebra WT41N0 and a RS507 bluetooth scanner, I am also using a TE applications and an AS400 has the host. The issue that I am having is that the user will be working and moving along just fine, they scan a barcode and then nothing happens, the scanner will not product a beam. When I remove and reinsert the battery I get the start up LED's and then it goes back to doing nothing. The only way to fix it is to have the user log out and then reboot the terminal and pair it again. Also the user will be working and the pairing barcode will pop up for unknown reason and asked to be paired again. I tested it with a fully charged battery and it happened to be. I put the scanner in pick list mode and enabled the low battery warnings but I did not get any warnings about battery getting low. Are there any ideas of what could be happening? Thanks

Text Goes Off Screen - Wavelink, Produce Pro

$
0
0

Hey everyone,

 

I've been having this issue with my MC9190s and MC92N0s for awhile now and I still haven't figured it out.

 

Basically we run using Produce Pro and the text seems to be running off the screen. I'm not allowed to take the simple route of just enabling the horizontal scroll.

 

Here's what going on:

 

RawyQPe.jpg

 

 

As you can see, the text cuts off at 2. There is more after this. Look below: (All I did to get it all to display for this picture is take the text down to 11 rather than having it at 13, however its far to small.)

 

 

 

OhiST6Y.jpg

 

 

 

It doesn't just change the login screen, it happens all through the software. It's super hard for them to do their job when this is happening. Any ideas?

Advance page in Zebra MC32 in Wavelink Terminal Emulation

$
0
0

Hello.

 

I need to configure some Zebra MC32 devices (Windows CE7) with a page advance key in Wavelink TE.

Can you tell me how I can configure it?

 

Thanks in advance.

Carlos

barcode scanner on telnetCE, device intermec CN51

$
0
0

Hello

ii worked before on cn70 and telnetce, but now i received new intermec cn51.

Installed:

WLTE_UNI_WM65_LANG_7_3_225_AS.exe

on telnetCE, barcode scanner dont write data, outside TelnetCE screen, works fine

 

changed this parameters but no luck

Emulation Parameters:

    1. Scanner then Common and "Disable Scanner" to YES

    2. Scanner then Common and "Use Scanner As Keyboard Wedge" to ENABLE

 

could you help me?

thanks in advance

Direct link for TelnetCE app for Motorola MC9090 ?

$
0
0

Direct link for TelnetCE app for Motorola MC9090 ?

SAP time out error 400

$
0
0

Hello,

We are using the Wavelink TE industrial browser.

 

I'd like to know how to handle the browser error 400.

This happens when a user's logon has timed out in SAP.

 

I would like to have the scanner go back to the site that is configured in the host profile.

Right now it stays on the error screen.

We have the browser menu hidden, so the only way for the user to get back to the URL in the host profile is to re-boot the device.

 

There is an option in the emualtion coniguration to re-direct the user to a URL if there is a 404 error.

Is it possible to do something like this when tere is a 400 error?

 

Thanks

Doug


F5 function key is not working in SAP ITS screens

$
0
0

Hi experts,

 

We are using SAP ITS RF and wavelink browser on intermec CK3x devices. We are having an issue with F5 function key. When F5 is hit, the screen just refreshes and it does not do the intended action. It looks like the key code "F5" is not being recognized by ITS template.

 

In the ITS template, we have maintained the following meta tag for "F5".

<META HTTP-Equiv="OnKeydispatch0x74" content="Javascript:setFKey('5');">

 

The keyboard test gives the following key codes for "F5".

F5 = 3F00 under the keyboard test

F5 = 0074 under the windows keyboard test

 

Am I missing something.?

 

Thanks in advance.

I have successfully downloaded .reg file to the correct location on an MC45 Motorola Scanner, but I want to automatically run/regmerge the file what Avalanche command do I use

$
0
0

I want to run a .reg file automatically via Avalanche script, can someone post the syntax for this please

I am unable to get the Caps Lock to work in Wavelink for Android using MC9200

$
0
0

I have a brand new MC92N0-GA0SYEAA6WR with Android.  I am using Wavelink Terminal Emulation Version 2.0.16.4933

 

This is one of the first Android versions of the MC9200 that we have purchased.  We hope to switch to these and move away from the Windows CE devices we have used exclusively.  I am working to get the Android device operational in our environment and we require that the caps lock be engaged at all times when in Wavelink.  I went to configure the emulation parameters and made sure Initial Caps Lock State was checked.  I restarted Wavelink to have that change take effect, but when our login screen comes up, it is still all in lower case.  I went back into the emulation parameters and saw that the change I made was still there.  I decided to also check Initial Caps Lock State under VT Emulation.  This still resulted in all lower case.  I checked out one of our Windows handhelds and confirmed where I thought the Caps Lock was toggled in the Configuration Tool on my laptop.  However, I was unable to find a location in the Wavelink software on the handheld where Caps Lock was toggled.  Our Windows devices do work though.  Caps is always engaged.  I am not sure what I am missing with the Android device.  Is this something that simply cannot be changed in the Wavelink client?  Any help would be appreciated.  I found out we have 55 of these Android handhelds on order so I need to find a solution.

 

Thanks!

Key Indicator ( Ctrl/Alt/Numeric/Upper case/Lower case)

$
0
0

Hi,

Had been using Honeywell D6500 (WinCE5.0) with Wavelink for the model.

On the Wavelink, it shows the special keys ( Ctrl/Alt/Numeric) on the Wavelink Telnet Emulator.

But when upgrade device to Honeywell D6510 ( WinCE6.0), there is no Wavelink TE for it and had to use Universal version.

The universal version does not support special key indicator and therefore not able to show if CTRL/ALT/Numeric is keyed.

Is there no way to show them? Or will there be a version that will support D6510?

Is the MOT_MC92N0_CE7 Wavelink Product Configuration still supported?

$
0
0

We have MOT_MC92N0_CE7 Wavelink Product Configuration installed on a PC. It is not communicating via USB. Is there a Windows 10 version? Is the product even still supported?