Datalogic Jet - how to instal Wavelink Avalanche on it?

$
0
0

Hello,

i wanted to set up a new Datalogic Jet on our Wavelink Server.

but The device has no Wavelink Avalanche software instaled.

How can i instal the Software on the device?

tried to Copy the Wavelink Avalanche Software from Kayman Device but the WiFi doesn't work with this i think this version is not compatible with the Jet Device.


How to append a F5 key to the scan data

$
0
0

How to append a F5 key to the scan data.


Wvavelink TelnetCE v7.3.164

Emulation : IBM-5251-11

 

please help thank you.

Session Lost using wavelink studio

$
0
0

We are trying WT41N0 devices running Windows CE 7.0 and Wavelink Studio Client. We are having an issue when the devices go into power save.

When we wake them up again and wait for it to reconnect to the WifI, we cannot continue with our application. The device goes back to the wavelink studio screen with a 'session lost' message'. This does not occur with our WT4090 devices running under Windows CE 5.0 (and wavelink studio client).

 

I ran a log on the WT41N0 and have attached it.

 

Any suggestions would be appreciated.

Esc key not functioning in terminal session

$
0
0

Hello,

 

We recently received several new devices with Windows Mobile 6.  With these new devices I am unable to get the Esc key to register when in an active Terminal session.  I brought up the keyboard test,  and no value is returned when I press the Esc key.  Regular letter and number keys are returning the proper codes.  If I press the Esc key on the emulation keyboard the proper value does show up.

 

I have gone over and over the configuration settings without success.  I've compared the working device settings to our new device settings and can't find any differences.  It seems like I must be missing something simple.  Any assistance is much appreciated.

 

Device:  Motorola VC6090

Wavelink TelnetCE version:  7.3.79

WLTE 7.3.163 CK3X SSCC code128 how do you disable ]c1?

$
0
0

In WLTE 7.3.163 for the Intermec CK3X how do you disable ]c1 identifier from processing in a SSCC (GS1-128) barcode?

How to take over a Wavelink configuration

$
0
0

Hello, I have some Motorola MC9100 and I'd like to take over the configuration from one device to another device. I heard that I could copy the Termcfg.bin from the application\wavelink folder (via Active Sync) to another MC9100 but that don't work. If I looked in the Termcfg.bin I didn't find my configuration profile.

In which file is the configured profile from my Wavelink Telnet (Version 7.3.40) saved?

 

Another possibiltiy to take over the profile should be the Wavelink TelnetCE Configuration Utility but I can't find a download. Is this software only available for

maintenance agreement?

 

I hope you can help me :-)

Thanky You

 

Olaf

Installation issues with Avalanche SE 5.3 on Windows Server 2008 R2

$
0
0

Hi there

 

We are attempting to install Wavelink Avalanche SE 5.3 on a Windows Server 2008 R2 box and are having issues installation PostgreSQL.

 

Steps:

  1. We run the program AvalancheSE_530572 and RemoteControl413.exe - say yes to install of both components
  2. - install RemoteControl -> proceeds OK.
  3. Installing JRE- proceeds to Avalanche installation
  4. Set the PostgreSQK super user account password to a non-dictionary word.
  5. The installer then runs through some dialogs:

          checking for postgresql

          copies many files

          installing the jre...please wait

 

6. installing database support

7. creating database

 

Then it shows:

8. running database script file

- 4 times

 

9. Then fails with: "installation cannot continue due to the following error:

 

org.postgresql.util.PSQLException: Connection refused. Check that the hostname and port are correct and that the postmaster is accepting TCP/IP connections."

 

It appears that PostgreSQL fails to install. I have actually tried to manually install PostgreSQL a few days ago- thinking that Avalanche was simply failing to connect to an existing instance.

 

The Windows firewall is OFF. I am logged on as an administrator.

 

I was wondering where I can go to get more logging information and hopefully find out what is going on here.

 

Bright ideas welcome!

 

Regards and thanks

 

Tim Muir

RFBS

Scan Handler - Removing specificed string from the start of a Barcode

$
0
0

Hi I'm trying to configure my RF Guns to remove any barcode that starts with "1P" and that starts with an "S".

 

I have the following code written for the removal of the S but it doesn't seem to be working. Can anyone correct my mistake or show me where I'm making the error. Thanks very much!

 

Syntax= A(0){0,S}[SS]

 

Sam


Why is pre licensed terminal emulation asking for a licence on one of my customers unit?

$
0
0

Hi, i have just loaded 10 units with pre-licensed software (mc9090, wm5, ver:7.0.133)  for a customers and the last unit he powers up is asking for a licence? Can someone advise why?

 

 

Thanks in advance.

Where i can find TelnetCE pre-license number for my symbol MC3190?

$
0
0

I have bought Symbol MC3190 (not new). After installation of Telnet CE 7.0 (pre-licensed on this devises), it asks me for license number. Where i can get it?

why use device-specific enabler?

$
0
0

I'm working with Motorola MC55 devices and Avalanche SE.  I'm finding that the AVA package for the device-specific enabler has no configuration options -- is this the intended design?  If so, why would I choose to use that enabler instead of the generic enabler package, which has the expected enabler configuration options available to deploy?

 

Thanks,

-Ben

ERROR: Session lost.

$
0
0

Hi,

 

after a repair, a device comes back to us. I try to install the universal enabler 5.2, which succeeds. Upon connecting however, the log shows ERROR: Session lost.

 

what could be causing this?

 

cheers,

Errant "?" inserted into scans in TE on Thor VM1

$
0
0

I have a Windows Embedded (XP flavor) Thor VM1 running the universal client of TelnetCE with the Link*One software being used as the scanner wedge. Using TE as the scanner wedge was not a viable option as "?"s were inserted in between every character when using a serial scanner.

 

Using Link*One has worked out great so far except for we are now running into a situation with TE inserts a "?" in scans of barcodes that contain hyphens. Outside of TE the barcode scans absolutley fine and even from a putty session to the same VT host the barcode scans fine. But in TE a "?" gets inserted.

 

How can this be removed? It seems to only be affecting Wavelink TE.

 

Sample barcode:

Barcode.JPG

 

Barcode scanning into Putty session (scan is after Tsk#) and Notepad. Notice no ? is inserted in either case:

2014-04-17 08_57_01-Greenshot.jpg

 

TE session with the ? inserted after the scan (after Task#):

2014-04-17 08_58_14-Greenshot.jpg

 

What's the deal?

control radio type (b/g/n) on Motorola MC55

$
0
0

Hi Folks -- trying to force a radio mode (802.11b/g/n) on MC55's but don't see a way to do so in the GUI.  Is this something that can be adjusted in a PRF file manually or as a custom property in the WLAN settings of the network profile?

 

Thanks,

-Ben

Industrial Browser Wavelink

$
0
0

We have planning to running project of Warehouse Barcode using SAP-ITS, but before project running we need to prepare environment. Related Wavelink Industrial browser, please inform to me what limitation of trial/demo version? (please specify).

Thank you for your information.


Enabler 5.3-38 set country code for WT41N0

$
0
0

Hello,

 

I have tried to set the country code with Enabler on Motorola WT41N0

 

but it doesn't work.

 

In the enabler I have added this registry key

 

HKEY_LOCAL_MACHINE\Software\Wavelink Unified Network Interface\DDI

"CountryCode"=FR  ( and I have also tried FRA )

 

but the country code never change

 

 

The only thing that is works is the 802.11d  and the wireless profile

 

regards

 

Sebastien

How to have loudly sound on MC3190?

$
0
0

Hello,

on MC3190 when we use Telnet CE ( any version) the level of the sound is not enough loud to be hear by a end user in the warehouse

 

we need to know how we can set correctly TelnetCE to have a very heavy sound

 

thanks

 

Sebastien

WT4100 StartUp Problem

$
0
0

We just got new WT4100 from our distributor. Using with TelnetCE at version 7.3.144 (5250 and WT100 sessions). The problem we are facing is that after boot an aoutostrup applican  (WT41NOSTARTUP) is automatically launced by the system. This application is undesired and in conflict wiith the one (TelnetCE) we configured to startup.

 

The main question is how to remove the WT41NOSTARTUP application from startup. We already checked that the application is not defined into the startup folder. Also can see that the WT41NOSTARTUP has a shortcut onto the desktop. If we remove from the desktop at next boot it reappers.

 

Regard Antonio.

TelnetCE Host Type WEB is not Licensed on MC9190?

$
0
0

Hi Friends!

We have 5pc Motorola Symbol MC9190-G on Windows CE 6.

We want to use TelnetCE 7.3.146 or 7.0.94 (that installed) as Industrial Browser. But if I use Host Type "WEB", Demo-License message appear.

I read post Pre-Licensed Terminal Emulation Client for Motorola Devices, at top of page I saw NOT WEB Emulation.

We need to buy license for use TelnetCE as Industrial Browser?

How to I remove applied profiles from a device after the profile has been deleted?

$
0
0

Using Wavelink SE 5.3.0.572, I have created and applied network and software profiles to some of my devices and found them to be in conflict with previously applied profiles. I then deleted my newly created profiles. Now when I look at the applied profiles in my device's properties, it still lists the deleted profiles as applied. How do I remove an applied profile that does not exist anymore?