Quantcast
Channel: Ivanti User Community : Popular Discussions - Supply Chain (formerly Wavelink)
Viewing all 7290 articles
Browse latest View live

F5 function key is not working in SAP ITS screens

$
0
0

Hi experts,

 

We are using SAP ITS RF and wavelink browser on intermec CK3x devices. We are having an issue with F5 function key. When F5 is hit, the screen just refreshes and it does not do the intended action. It looks like the key code "F5" is not being recognized by ITS template.

 

In the ITS template, we have maintained the following meta tag for "F5".

<META HTTP-Equiv="OnKeydispatch0x74" content="Javascript:setFKey('5');">

 

The keyboard test gives the following key codes for "F5".

F5 = 3F00 under the keyboard test

F5 = 0074 under the windows keyboard test

 

Am I missing something.?

 

Thanks in advance.


Wavelink in MC9090 and MC9060?

$
0
0

Hi,

 

I bought two MC9000, one MC9090 and one MC9060. And I need check or installa on PDAs:

 

Wavelink Emulator Telnet installed. With WEB adapter. with Windows CE 5.0 running WaveLink Telnet CE Version 7.0.x

 

So, please can you help me?

 

Thanks

 

Luis

Wavelink TelnetCE 73197 Display Language - UTF8

$
0
0

Hello.

I have Motorola MC3190 and TelnetCE 73197. I need select UTF8 in "Display Language". It is demand for correct display Russian language in the programm. I do not see UTF8 in list "Display Language".

How i do it?

Best regards,

   Andrey.

Wavelink Avalanche 5.3 - Orphaned package shouldn't be orphaned.

$
0
0

Hi All,

 

We are experiencing some trouble with our Wavelink Avalanche 5.3 server: We use the TelnetCE application package and push that to our Psion VH10f terminals. In that package is also the URL to where the industrial browser should go. When changing the URL to a new one the server deleted that package from all our terminals and marked the package as "orphaned". Nothing else but that URL was changed to the application package. When i open the list (see screenshot) of orphaned packages to delete, the industrial browser package is in the list.

 

Wavelink 1.jpg

 

I found out that there are 3 reasons why a package would become "orphaned":

* if it has been deleted from the Avalanche Console,

* if the software profile it belongs to has been disabled,

* or if the package has been disabled.

 

Well i checked and confirmed all 3 situations:

Wavelink 2.jpg

 

The package "criteria" is also an correct since it has always worked, didn't change and i double checked if it is correct at this moment.

 

Does anybody have a clue why the server is claiming it to be "Orphaned" or is there any way to force the server into believing that that package shouldn't be "orphaned". We also tried rebooting the server but the problem persists although it shouldn't be orphaned.

 

Thank you for your time

Kind Regards

Wavelink Telnet CE - How to send Function key by barcode scan (5250 emulation)

$
0
0

How can I setup Wavelink TelnetCE v. 7.0.108  (5250) to send F12 key when I scan a F12 barcode for exemple ?

Studio Client Emulators

$
0
0

As a developer that works with Wavelink Studio COM, I would greatly appreciate the folks at Wavelink to publish any Studio Client Emulators with instructions on how to tailor them to emulate certain aspects of different scanner devices (like being able to change the "wlclient.cfg" file).

 

I am aware that the new version of the Studio COM Server (v3.8) comes with an emulator, but this emulator does not seem to emulate the appearance of the UI as it would appear on an actual device. It also exhibits glitches where buttons no longer respond, and I can't figure out how to simulate scanner input. This makes program development difficult.

 

Four years ago, I was supplied with an emulator by someone that works at Wavelink that can't be downloaded from the Wavelink website. This emulator works very well, and it calls itself "Wavelink Windows Studio Client". This emulator allows me to make adjustments to its configuration in the same fashion as I would change the configuration on a standard Studio Client via the "wlclient.cfg" file. This means that I can reliably see how the UI is drawn for a device with a wide screen (such as the Motorola WT 4090), and how the UI is drawn for a device with a long screen (Such as the Motorola MC 9000 series).

 

Screenshot from the older "Wavelink Windows Studio Client":

oldEmulator.jpg

 

New emulator packaged with Studio COM Server v3.8 (note the different default font for the Widgets and flagrant difference in display behavior):

38emulator.jpg

 

(**Note: the screenshots you see were taken from the two emulators running the exact same application from the same Studio COM Server. )

 

 

Suffice it to say that I am content with the older emulator that I have in my possession, and I am still able to use it when connecting to a v3.8 Server. However, newer devices on the market (example: Motorola MC9190G) seem to feature a different display technology that makes the UI on the Studio Client appear extremely small. Older models used QVGA technology (Quarter Video Graphics Array), where these newer models have begun to use the standard VGA technology that has a higher resolution than QVGA, hence the smaller appearance of the UI. Under normal circumstances, our programmers would be able to rescale the form automatically in the code, but Studio COM provides no such capability in its API. This makes us dependent on Wavelink to provide client software that is properly calibrated for the device in such a way that maintains consistent appearance and behavior across all other supported devices.

 

Since the emulator I have depended on for four years is no longer reliable in fulfilling its purpose, I'd like Wavelink to supply me with the tools and instructions so that our programs will function with reliable consistency using the Studio COM API as directed.

SAP time out error 400

$
0
0

Hello,

We are using the Wavelink TE industrial browser.

 

I'd like to know how to handle the browser error 400.

This happens when a user's logon has timed out in SAP.

 

I would like to have the scanner go back to the site that is configured in the host profile.

Right now it stays on the error screen.

We have the browser menu hidden, so the only way for the user to get back to the URL in the host profile is to re-boot the device.

 

There is an option in the emualtion coniguration to re-direct the user to a URL if there is a 404 error.

Is it possible to do something like this when tere is a 400 error?

 

Thanks

Doug

Wavelink application disappeared from Motorola MC9090

$
0
0

Hello,

Recently I have a problem with Motorola RDT MC9090 with Wavelink Terminal Emulator on them.

Problem description:

Wavelink TE application is gone on 3 MC9090 RDT.

I have check:

- application folder,

- program files folder,

- windows folder.

No sign of Wavelink application. It is gone from the RDT drives, where it was previously installed.

Previously my collogue simply re-install wavelink application, but this is not a solution for me, because it seems like the problem is frequently repeating.

Some details about my hardware and software:

Device: Motorola MC9090

OS: Windows CE 5.00 (build 1400)

Terminal software: probably wltn_mot_9000_ce50_7_0_92_as

I will appreciate any help.

Thank you.

 


Function keys with WT41N0 Telnet CE 7.3.192 VT220 emulation

$
0
0

Hi i'm having difficulties using function keys with Motorola WT41N0 Telnet CE 7.3.192 and VT200 emulation. Random charachtes or error message key not recognized is diplayed if i'm trying to use Function keys (F1; F2 etc.) Any ideas?

Remap function keys

$
0
0

Hi,

 

I'm trying to remap F1 to [ALT][F1] with the Wavelink TE Android's version for a Panasonic FZ-A1, as far as I know F1 stands for 3B00 , but I don't know wich scape secunce stands for [ALT] key, and hoy to concatenate it with the [F1].

 

¿Does any of you has an idea about how to solve it?

 

 

Thanks in advace,

Creating an Application package from existing *.exe on device

$
0
0

If i select Application from package type it is not possible to use an already existing *.exe file on the device. How is it possible to set only a link to the Wavelink view with an existing file on the System without copying the *.exe again to the device ?

 

Thanks for soon help

 

Ralf

How to check a file exists or not on the mobile device via Wavelink AMC?

$
0
0

Scenario:

 

File :StartUpCtl.exe

Location on the handheld:Application\Startup

 

Before deploying we need to check what devices lack the exe file as a precheck.

How to have loudly sound on MC3190?

$
0
0

Hello,

on MC3190 when we use Telnet CE ( any version) the level of the sound is not enough loud to be hear by a end user in the warehouse

 

we need to know how we can set correctly TelnetCE to have a very heavy sound

 

thanks

 

Sebastien

HowTo disable hardware keyboard within VT100 emulation?

$
0
0

Hi all,

 

I need to disable the hardware keyboard from with in a VT100 emulation session.

Is it possible to start an external application (whitch toogles the keboard between on and off) by scanning a specific barcode?

Or, mybe somebodey has some other ideas?

 

I would appriciate your help, thank you.

 

Greetings

Diego

How to Enable Spanish Support on Wavelink Emulator v 7.0.159 MC9090 CE5

$
0
0

Customer has installed the Wavelink Emulator v 7.0.159 with International Support on his Motorola MC9090 running CE 5.  States the host is set up to send Spanish characters to the client devices.  Has set a language in the Host Profile for Display but not working.  What language needs to be chosen here for Spanish support and what additional settings are necessary?


can I get a copy of AvaCfgCE version 5.3-05 package

$
0
0

can I get a copy of AvaCfgCE version 5.3-05 package?

telnet server could not log you in using ntlm authentication

$
0
0

I am getting this message and Win7 immediately closes the session.

 

anything that I should do on Win7 telnet server side?

It's the same all for windows mobile 6.5 and android clients.

 

thanks

Configuration Function Key F5 and F6 to TE VT220

$
0
0

Anyone knowthe configuration ofkeysF5andF6function inVT220emulation?


I have a customer usgin SAP VT220 emulation.

 

 

I triedthe settings below,butit did not work

F5 - 3F00:\3F00\000D

F6 - 4000:\0336\000D

 


read RFID tag using RFIO object Studio Client on MC9090-G Handheld Device

$
0
0

We are trying to read RFID tag using RFIO object  Studio Client on MC9090-G Handheld Device. And not understand how switch input for RFIO between laser barcode scanning and RFID reader? 

This metod https://community.landesk.com/support/docs/DOC-29973 not suitable for me , because Wavelink Symbol 9090 WM5.0 Studio Client not contain RFID Enable Key .

Any help would be appreciated, thanks!

How to read TID + EPC + RESERVED + USER MEMORY in the same time?

$
0
0

Hi...

 

I'm sorry for to opened in the last days two wrong request, and I removed them, but I studied a lot the problem I have and now I found what I would to ask.

When I use the Wavelink Telnet CE with RFID scan, I noticed that the data read is only the EPC. I tried to change the setup of RFID MEMORY BANK and RFID MEMORY BANK FORMAT using the different options, TID, MEMORY BANK but I found only the TID or MEMORY BANK datas (if I use MEMORY BANK it gives me 8 hex chars + EPC data) but not the union of the two datas.

 

For example I take 4 RFID's labels and checked with the scanner that they have 5 different TIDs (for semplify I think they have 01, 02, 03 values).

Now I create on these labels the EPC datas (for semplify I'll give them the same value for all: AAAA).

 

Now I have 3 labels with TID=01 EPC=AAAA and TID=02 EPC=AAAA and TID=03 EPC=AAAA. If I use the scanner on the Wavelink Telnet CE (a Motorola 3190Z handheld) to scan these RFID labels, it read only one label with EPC=AAAA 'cause all have the same EPC value.

 

If I use the VBRFIDSample6 software in Visual Basic installed on the handheld, it gives me the same result, one record with EPC=AAAA but read 3 times.

If I try to read only the TID, it gives me only 1 TID and not the others (read 3 times) and not the original 01 or 02 or 03 values but another value.

I don't understand if there's a mistake when I write the labels and make the wrong operation overwriting the original TID (I don't know if it's possible and I know isn't possibile) or if there's a setup or a parameter on the scanner Wavelink software to let me to read not only TID, or EPC, or User Memory, or Reserved, but all these datas in the same time.