Quantcast
Channel: Ivanti User Community : Popular Discussions - Supply Chain (formerly Wavelink)
Viewing all 7290 articles
Browse latest View live

License server problem

$
0
0

We have installed license server 4.3 and buy licenses. But license server not provide licenses to PDA (license request rejected).

Log:

+05614141 1: License socket (1820) received 66 bytes of data from address 192.168.8.122:2001

+05614141 1: Platform Request received from address 192.168.8.122:2001

+05614141 2: No "Velocity 1.0 CE" licenses available for MAC Address 0017230BEB17, Site ID 1

+05614141 2: No "Velocity 1.0 CE" licenses available for MAC Address 0017230BEB17, Site ID 0

+05614141 1: Platform Request: platform "Velocity 1.0 CE" is not available

+05614141 1: Platform Request: Not sending a platform response to address 192.168.8.122:2001

+05614516 1: HTTP request header: GET /licenses.html HTTP/1.1

Host: 192.168.0.19:4420

Connection: keep-alive

Authorization: Digest username="admin", realm="Wavelink Client License Server", nonce="5da29c38eef6af3208c21f574dd86664", uri="/licenses.html", response="c71fd5332c51ee42fa2fd91bf1b14652", opaque="d2abaa37a7c3db1137d385e1d8c15fd2", qop=auth, nc=0000017f, cnonce="fc37e2ce7c90a9f6"

Upgrade-Insecure-Requests: 1

User-Agent: Mozilla/5.0 (Windows NT 10.0; WOW64) AppleWebKit/537.36 (KHTML, like Gecko) Chrome/53.0.2785.101 Safari/537.36 OPR/40.0.2308.62

Accept: text/html,application/xhtml+xml,application/xml;q=0.9,image/webp,*/*;q=0.8

Referer: http://192.168.0.19:4420/configlogging.html

Accept-Encoding: gzip, deflate, lzma, sdch

Accept-Language: ru-RU,ru;q=0.8,en-US;q=0.6,en;q=0.4

If-Modified-Since: Fri, 25 Sep 2009 09:14:34 GMT

 

+05614516 1: HTML object 'licenses.html' loaded from cache

+05614516 1: HTTP response header: HTTP/1.1 200 OK

Date: Thu, 29 Sep 2016 09:53:04 GMT

Server: Wavelink Client License Server/4.3.006

Content-Type: text/html

Content-length: 9049 

Last-modified: Fri, 25 Sep 2009 09:14:34 GMT

Expires: Thu, 29 Sep 2016 09:53:04 GMT

Cache-Control: no-cache


Is Picklist Mode available on the PreLicensed MC9190 CE

$
0
0

Is Picklist Mode available on the PreLicensed MC9190 CE Operating System. I have downloaded and installed the MC9190 CE Emulators v7.0.122. Once it is installed on the PC I then go to Scanner/Common and expect to see "Pick List Mode". On the MC9190 CE TE there does not seem to be Pick List, however on the MC9190 WM TE there IS a "Pick List Mode".

RS507 bluetooth scanner locking up

$
0
0

I am using a Zebra WT41N0 and a RS507 bluetooth scanner, I am also using a TE applications and an AS400 has the host. The issue that I am having is that the user will be working and moving along just fine, they scan a barcode and then nothing happens, the scanner will not product a beam. When I remove and reinsert the battery I get the start up LED's and then it goes back to doing nothing. The only way to fix it is to have the user log out and then reboot the terminal and pair it again. Also the user will be working and the pairing barcode will pop up for unknown reason and asked to be paired again. I tested it with a fully charged battery and it happened to be. I put the scanner in pick list mode and enabled the low battery warnings but I did not get any warnings about battery getting low. Are there any ideas of what could be happening? Thanks

need to install cab file to intermec CK3X device

$
0
0

AVA 5.3 SE

intermec CK3X 

OS - 5.2.29217(29217.5.3.12.26) 

fw: 1.61.22.0072


Hi

Need to install customer application to the above Intermec CK3X device.  Customer application is cabbed up but  does not automatically install.

Would anyone be able to suggest method to install this cab automatically on this intermec device?  I was thinking create package(via package builder)  and use the wceload.exe cmd in the post install script.  But, wceload.exe is not visible on the device so not sure if this will work or not.  i do know there is another method with intermec devices where you can copy the cab to the flashfilestore\cabfiles folder and reboot the device.  this installs the cab file successfully.  not sure how to code this in the package builder.  any assistance would be appreciated.

TE client with WIN10

$
0
0

I need to install TE client configurator on Windows 10 but when the setup start give error: missing RAPI.DLL...how solve this problem with WIN10?

 

Thanks

Issue Enter After Barcode Scan

$
0
0

Hello:

I am currently testing a Zebra WT6000 and an RS6000 ring scanner. I have set up a project within the Velocity Console (Ver. 1.2.101) and have deployed that project to the WT6000. When I scan a barcode, I need to issue and Enter key and am not sure how to do this. DataWedge is also installed on the WT6000 with a Velocity Profile and I have enabled Send ENTER key in the basic data formatting. However, when I exit the DataWedge application it does not seem to save that information.

 

Thank you.

What License is needed to purchase to get TelnetCE Client with WEB-Emulation for a Motorola MC9090??

$
0
0

What License is needed to purchase to get TelnetCE Client with WEB-Emulation for a Motorola MC9090?

Problem with the deinstallation of the Wavelink TelnetCE 7378 application

$
0
0

I am currently about to deinstall / install the Wavelink TelnetCE 7378 application on our Motorola MC9100 device. In order to achieve this, I have already tried the following measures without any success:

 

(1)      Deinstallation via the Motorola Wavelink Application (Application & Config):

 

After having executed the deinstallation process I get the following error message despite the fact, that the application is already installed on the device:

 

"Update failed. Unable to determine install directory. Please verify that the product is installed on the device."

 

(2)     Deinstallation via the remove programs menu on the scanner

 

It is written on the screen: "Programs in storage memory: Wavelink TelnetCE 7378". I mark the entry. Afterwards I click on "remove". After having clicked on "remove" the following error appears:

 

"Wavelink TelnetCE 7378 was not completely removed. Do you want to remove it from the list of installed programs?" Then I click on "yes" but nothing happens.

 

(3)      Reinstallation of the client via the "Application & Config" button on the application:

 

The reinstallation process starts. However I get the following error messages on the screen:

 

"The previous version of Wavelink TelnetCE 7378 will be removed before the new one is installed. Select OK to continue or cancel to quit". I click on "OK". After three seconds the following error message appears:

 

"The previous version of Wavelink TelnetCE 7378 cannot be removed. Do you want to continue installing Wavelink TelnetCE 7378?" Here I click on yes. Then the following message appears:

 

"Installation of Wavelink TelnetCE 7378.cab was unsuccessful."

 

(4)      Restarting of the Scanner and the following of the reinstallation / deinstallation measures (Bullet points 1 - 3) as described above after the scanners’ reboot was also not successful

 

(5)      The deinstallation of the Wavelink Application and the following of the reinstallation / deinstallation measures (Bullet points 1 - 3) as described above after the scanners’ reboot was also not successful

 

 

So I have now tried five possibilities to solve the problem. Do you have any other hints regarding the solution of this issue?

 

Thank you very much in advance.


Can you remap keys in Telnet for a Zebra MC3200?

$
0
0

I have an end user who would like the green button on his MC3200 to function as Esc, and the red button to function as F3. Can these be remapped within Telnet, or is this something that will need to be done on the device itself?

Different Key Macros per session

$
0
0

We are under Wavelink Telnet on Windows CE

 

We have two sessions, one is VT220 and the other is 5250

 

since pressing F5 transmit nothing by default under a VT session, whe've added a Key Macro to generate Esc[15~ (mandatory in my customer's application)

 

the problem is when we switch to the 5250 session and press F5 : the same key macro is generated instead of the expected 5250 F5

 

Is there a possibility to specify in a key macro which session is concerned to avoid this problem ?

 

Thanks

How do I limit the number of Sessions in Velocity to one?

$
0
0

I know in Wavelink telnet you could use multiple sessions, up to four.  Is this the default in Velocity?  How do I limit the number of sessions to only 1?  To only 2?

Has anyone used the Studio Client for iOS? I am unable to install on any device.

$
0
0

I would like to try out the Studio Client for iOS. I have followed the step in the documentation but get an error (the application could not be verified) when attempting to install on iPhone or iPad. The instructions are not clean on what versions are supported. Has anyone had any luck and if so with what devices and versions?

 

Thanks

Alex

MC9190 and MC92N0 with 2 host profiles and 2 sessions.

$
0
0

customer is using MC9190 and MC92N0 with 2 host profiles and 2 sessions.

 

 

MC9190

Windows mobile 6.5

Telnet version 7.0.122

 

 

MC92N0-G30SXERA6WR

Windows mobile 6.5

Telnet version 7.3.196

 

 

The telnet settings and both the units are configured the same.

 

 

One host profile connects to AS400 and the other host profile connects to IBM

 

 

With MC9190 customer is able to connect to both the sessions. They are able to switch between 2 sessions.

 

 

However, with MC92N0 if customer tries logging in to both the sessions, it logs out the other session. At one time customer is able to log to one session only.

 

 

Is there a known issue? Are there any settings that we need to change on MC92NO?

Velocity TE - how to map keys for MC92N0 / keys not working.

$
0
0

We need to remap some keys for the MC92N0 to match application functionality in a TE / VT220 emulator.  I see that there is a ReplaceKey script in the LIbrary as an example, but it doesn't seem to work even when I hard code keyscan values.  Is there a different/easier way?

TelnetCE Autologin Command Prompt not excecuted (return/enter not sent to the host)

$
0
0

Problem with Autologin feature which will stop and wait for user to press ENTER instead of executing command automatically.

 

Setup:

Wavelink TelnetCE - Host Profile - Autologin:

Name Prompt: "login:"

Name: "myuser1"

Password Prompt: "password:"

Password: "mypwd" (displayed as "*****"

Command Prompt: "domain:"

Command: "mydomain.com"

 

Result of connection test:

Autlogin correctly sets and executes login and password but for domain prompt only presets value "mydomain.com" and does not execute it (waits for user to press ENTER).

 

Expected result:

Return/ENTER is sent to host to execute the command.

 

Remarks:

The same problem occurs also for standard command (e.g. D:\MyApp\start.bat) when domain prompt is removed in the server setup.

 

Enviro:

Host: Windows Server 2008 R2 64bit, Georgia Softworks Telnet Server 8.05

Client: Motorola MC9190G, Windows Mobile 6.5, Wavelink TelnetCE 7.3.237 (latest available)

 

Thank you,

Michal


How to have loudly sound on MC3190?

$
0
0

Hello,

on MC3190 when we use Telnet CE ( any version) the level of the sound is not enough loud to be hear by a end user in the warehouse

 

we need to know how we can set correctly TelnetCE to have a very heavy sound

 

thanks

 

Sebastien

Wavelink TelnetCE Application configuration autostart

$
0
0

Dear colleagues,

 

I'm struggling to get this configuration to work properly

The login and password are working fine, but the command is not being executed. I'm wandering what i should fill on the command prompts/responses fields, in order to get this done.

 

Basically what i need, is that whenever the client connects to my server, an specific BAT file must run automatically.

 

Thanks in advance for your time and support.

Marcus.

Enter after scanning only on a specific field

$
0
0

I am trying to send a barcode with an enter only on one specific field.  I do not need it send after every field just one specific scanned field. 

 

My issue with sending after every scanned field is because if a scanned barcode fills a field it will automatically jump to the next field and then skip it or blank out previous data. 

Wavelink in MC9090 and MC9060?

$
0
0

Hi,

 

I bought two MC9000, one MC9090 and one MC9060. And I need check or installa on PDAs:

 

Wavelink Emulator Telnet installed. With WEB adapter. with Windows CE 5.0 running WaveLink Telnet CE Version 7.0.x

 

So, please can you help me?

 

Thanks

 

Luis

Play beep sound

$
0
0

Hi,

I tried two options to play a beep sound when an error occurs in SAP ITS mobile.

1. BGSOUND

2. IDA_BEEP.

Both did not play the beep sound on the velocity browser on Intermec CK71 RF device. But, both played the sound when I used the internet explorer on Intermec CK71 RF device! 

 

Please let me know if need to use something else to play sound.

 

Code:

IDA_BEEP:

    <script type="text/javascript" language="javascript">

        if (typeof external.CETerm != 'undefined') external.CETerm.PostIDA( "IDA_BEEP", 0 );

    </script>

 

BGSOUND:

<bgsound src="/sap/public/bc/its/mimes/itsmobile/99/sounds/all/sapsounderr.wav" loop="4">

 

Device Details:

RF Device - Intermec CK71

Wavelink Velocity Client - Release 1.0.29 - 07/01/2014

Operating System-Windows Embedded 6.5 Classic. CE OS 5.2.29217 (Build 29217.5.3.12.26)

 

Thanks,

ER

Viewing all 7290 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>