Quantcast
Channel: Ivanti User Community : Popular Discussions - Supply Chain (formerly Wavelink)
Viewing all 7290 articles
Browse latest View live

Where can I download the TE client v7.3.x is both pre-licensed and pre-loaded on the following Windows CE devices: MC92N0?

$
0
0

Hi,

 

I need the TE client v7.3.x is both pre-licensed and pre-loaded on the following Windows CE devices:MC92N0

But the link, which in this article only shows a page without the source file.

 

Where can I download it?


Zebra Motorola MC9200 Windows Embedded Compact 7 Volume Power cold boot resistant

$
0
0

Got today the new MC9200.

Speaker ist terrible loud, so i set via control Panel the volume to Soft. After cold boot, the Sound ist set again to Default.

 

How can i prevent this. Windows Embedded Compact is new to us.

 

Thx

 

Ralf

barcode scanner on telnetCE, device intermec CN51

$
0
0

Hello

ii worked before on cn70 and telnetce, but now i received new intermec cn51.

Installed:

WLTE_UNI_WM65_LANG_7_3_225_AS.exe

on telnetCE, barcode scanner dont write data, outside TelnetCE screen, works fine

 

changed this parameters but no luck

Emulation Parameters:

    1. Scanner then Common and "Disable Scanner" to YES

    2. Scanner then Common and "Use Scanner As Keyboard Wedge" to ENABLE

 

could you help me?

thanks in advance

ck75, package deployment

$
0
0

Hi Everyone,

 

With the end of life annoucement for the MX7T, we are currently testing the CK75 as its replacement. We are running into a few issues with trying to use this device with Avalanche 6.0. The device will show up as LXE_UNKNOWN, won't allow us to remote into this device and won't pull up any of the statuses (signal quality, battery, etc). Any suggestions? Is the CK75 even supported with our version of Avalanche?

 

Thank you,

 

Krystal

SAP ITS Mobile on Honeywell CT50 Windows 10 IoT Mobile Enterprise and Android 6.0.1 Marshmallow

$
0
0

Hello everybody,

 

We are facing some problems, with Honeywell CT50 and Wavelink TE.

1) There isn’t a version for CT50 and the universal emulator for Windows 10 can not be installed on CT50 Windows 10IoT Mobile Enterprise.

2) We have installed a universal emulator for Android that we have downloaded from play store. Has someone experience with SAP ITS Mobile on Android OS?

 

Best regards,

Daniel

How I replace GS (Group Separator) from GS1-128 by "]" character ?

$
0
0

I need to replace a <GS> (group separator) when I scan a GS1-128 barcode by a "]" character. How can I do that using terminal config from Wavelink Industrial Browser?

Is there a way to emulate page up and page down for motorola MC3190 ?

$
0
0

Good morning,

is there a possibility to scroll up and down my screen when i'm using a wavelink 5250 emulation ?

 

I can't use any combination of keys or the up/down specific keys.

 

Can someone help me please?

Thanks.

Roberto

WPA2 AES not working

$
0
0

I have Datalogic Falcon X3's that have been in production for a while now our customer changed thier security encryption from WPA TKIP to WPA2 AES since the change our scanners will sporadically disconnect and not reconnect.


How to activate

$
0
0

Necesito instrucciones de activación en el terminal de Wavelink 2 in 1 TN.

He buscado información en el portal Ivanti pero no encuentro nada sobre este tipo de licencia.

gracias.

 

 

 

Purchaser: ARES SOLUCIONES DE IDENTIFICACION,

Sales Order Number: SO-00221728

Purchase Order Number: AX1CF9AF95DC

End User Purchase Order Number:

Order Date: 5/23/2017

 

Items Ordered:

 

Wavelink 2 in 1 TN Client Generic. for 1 Users/Devices

RS507 bluetooth scanner locking up

$
0
0

I am using a Zebra WT41N0 and a RS507 bluetooth scanner, I am also using a TE applications and an AS400 has the host. The issue that I am having is that the user will be working and moving along just fine, they scan a barcode and then nothing happens, the scanner will not product a beam. When I remove and reinsert the battery I get the start up LED's and then it goes back to doing nothing. The only way to fix it is to have the user log out and then reboot the terminal and pair it again. Also the user will be working and the pairing barcode will pop up for unknown reason and asked to be paired again. I tested it with a fully charged battery and it happened to be. I put the scanner in pick list mode and enabled the low battery warnings but I did not get any warnings about battery getting low. Are there any ideas of what could be happening? Thanks

Where are Avalanche licenses actually stored? In the DB or in the installation directory somewhere?

$
0
0

I understand that the licenses are added through the web console (6.x) and are visible in the same area, but where are they actually being stored? I am curious to know, based on a DR planning effort.

display the velocity keyboard automatically

$
0
0

On a Zebra TC8000, I would like the Velocity keyboard to appear automatically when you click in a field. I would not click on the keyboard icon to make it appear.

Currently, the original Android keyboard is displayed by default.

Is it possible to configure this?

Web console is not working after Apache Tomcat 7.0.42 patch

$
0
0

I am running AvalancheMC v 5.3.1.  I receive the following error when using the web console at http://{servername}:8080/AvalancheWeb/login.jsf:

 

HTTP Status 404 - /AvalancheWeb/login.jsf


type Status report

message/AvalancheWeb/login.jsf

descriptionThe requested resource is not available.


Apache Tomcat/7.0.42

 

This was working correctly before the patch. Any suggestions?

Where can I download Naurtech CETerm 5.7

barcode scanner on telnetCE, device intermec CN51

$
0
0

Hello

ii worked before on cn70 and telnetce, but now i received new intermec cn51.

Installed:

WLTE_UNI_WM65_LANG_7_3_225_AS.exe

on telnetCE, barcode scanner dont write data, outside TelnetCE screen, works fine

 

changed this parameters but no luck

Emulation Parameters:

    1. Scanner then Common and "Disable Scanner" to YES

    2. Scanner then Common and "Use Scanner As Keyboard Wedge" to ENABLE

 

could you help me?

thanks in advance


Motorola WT41N0 scanner with new Telnet Emulation version 7.3.153 problem

$
0
0

Dear colleagues,

 

I have problem with new demo Motorola Device Mobile Terminal WT41N0 (Windows CE 7.0)  with new vesion 7.3.153 of Wavelink Telnet emulation.I can not be able to scann when I am in Telnet emulation.The scanner is working in Windows normaly but when I am in Telnet it is just not working proparly.The scanner have scanner lane but it is not giving me any resault of scanning.please if somebody have some idea let me know.

 

Thank you very much.

5250 emulator issues with WT41N0 devices

$
0
0

We have purchased several WT41N0 devices in the last 4 months.  It seems like ALL of them are having issues with the telnet client in some way or another.  The user will be in the middle of a telnet session and them emulator suddenly closes.  OR, another issue is the scanner.  The user will be using the emulator and the scanner suddenly quits working.   Exiting and going back into the emulator fixes it. 

 

Has anyone had these troubles and how did you fix?

Wavelink TelnetCE 73197 Display Language - UTF8

$
0
0

Hello.

I have Motorola MC3190 and TelnetCE 73197. I need select UTF8 in "Display Language". It is demand for correct display Russian language in the programm. I do not see UTF8 in list "Display Language".

How i do it?

Best regards,

   Andrey.

TLS 1.2 support in Velocity?

$
0
0

Questions:

Does Velocity support TLS 1.2 protocol?  I am pretty sure this is yes.

  Does it support importing TLS certificates?

Wavelink Telnet CE - How to send Function key by barcode scan (5250 emulation)

$
0
0

How can I setup Wavelink TelnetCE v. 7.0.108  (5250) to send F12 key when I scan a F12 barcode for exemple ?

Viewing all 7290 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>