Function Keys not working on MC3190
How to make it works.
Function Keys not working on MC3190
How to make it works.
Anyone knowthe configuration ofkeysF5andF6function inVT220emulation?
I have a customer usgin SAP VT220 emulation.
F5 - 3F00:\3F00\000D
F6 - 4000:\0336\000D
Hi there,
I have a question about ConnectPro. I am running the 4.4.1 version for the first time. and i see in my data capture the following messages. what do they mean exactly?
the Discarded Host in particular. What do you mean by that?
2016-10-18 07:28:23.753 Host host1/192.168.55.10:23 ==>> Client proxy1/192.168.55.113:1174 (5 bytes)
000000: 0D001B5B 43 ...[C
2016-10-18 07:28:23.769 Host host1/192.168.55.10:23 ==>> Client proxy1/192.168.55.113:1174 (5 bytes)
000000: 1B5B3131 43 .[11C
2016-10-18 07:29:23.761 discarded Host host1/192.168.55.10:23 ==>> / (5 bytes)
000000: 0D001B5B 43 ...[C
2016-10-18 07:29:23.783 discarded Host host1/192.168.55.10:23 ==>> / (5 bytes)
000000: 1B5B3131 43 .[11C
2016-10-18 07:30:23.764 discarded Host host1/192.168.55.10:23 ==>> / (5 bytes)
000000: 0D001B5B 43 ...[C
2016-10-18 07:30:23.779 discarded Host host1/192.168.55.10:23 ==>> / (5 bytes)
000000: 1B5B3131 43 .[11C
2016-10-18 07:31:23.761 discarded Host host1/192.168.55.10:23 ==>> / (5 bytes)
000000: 0D001B5B 43 ...[C
2016-10-18 07:31:23.776 discarded Host host1/192.168.55.10:23 ==>> / (5 bytes)
000000: 1B5B3131 43 .[11C
2016-10-18 07:32:23.787 discarded Host host1/192.168.55.10:23 ==>> / (11 bytes)
000000: 1B5B3131 420D001B 5B306D .[11B...[0m
2016-10-18 07:36:11.785 discarded Client proxy1/192.168.55.113:1175 ==>> / (161 bytes)
000000: 2A485350 30303031 35313931 31653763 36653930 64636531 62333762 39346462 *HSP000151911e7c6e90dce1b37b94db
000020: 37386434 65386364 31646873 70766572 3B323B70 726F746F 636F6C3B 313B686F 78d4e8cd1dhspver;2;protocol;1;ho
000040: 73743B31 39322E31 36382E35 352E3130 3A32333B 64697363 6F6E6E65 6374686F st;192.168.55.10:23;disconnectho
000060: 73743B32 3B736573 73696F6E 69643B37 35356162 39633064 65373534 36396131 st;2;sessionid;755ab9c0de75469a1
000080: 61623662 32346531 37383538 3264383B 64617461 72656365 69766564 3B373738 ab6b24e178582d8;datareceived;778
0000A0: 35 5
2016-10-18 07:36:11.785 generated / ==>> Client proxy1/192.168.55.113:1175 (150 bytes)
000000: 2A485350 30303031 34306333 62666565 30643336 66366534 34396463 35373661 *HSP000140c3bfee0d36f6e449dc576a
000020: 61393833 35636335 64326873 70766572 3B323B73 74617475 733B313B 73657373 a9835cc5d2hspver;2;status;1;sess
000040: 696F6E69 643B3862 38356431 31343934 37343633 32373763 31633439 31626338 ionid;8b85d114947463277c1c491bc8
000060: 66306332 31643B65 72726F72 73746174 75733B31 3B746572 6D70726F 78797665 f0c21d;errorstatus;1;termproxyve
000080: 7273696F 6E3B342E 342E313B 70726F74 6F636F6C 3B31 rsion;4.4.1;protocol;1
2016-10-18 07:36:11.859 Host host1/192.168.55.10:23 ==>> Client proxy1/192.168.55.113:1175 (3 bytes)
000000: FFFD25 ..%
just purchased datalogic Falcon x3 guns, Connect Pro was already set up for Kymans. the term proxy is causing the guns to run extremely slow. if i turn it off they are fast. Not sure how to resovle. as far as i know the software I previously installed is still the latest version of Term proxy. can't seem to get help out of Datalogic and so far cannot get help out of
Hi,
I tried two options to play a beep sound when an error occurs in SAP ITS mobile.
1. BGSOUND
2. IDA_BEEP.
Both did not play the beep sound on the velocity browser on Intermec CK71 RF device. But, both played the sound when I used the internet explorer on Intermec CK71 RF device!
Please let me know if need to use something else to play sound.
Code:
IDA_BEEP:
<script type="text/javascript" language="javascript">
if (typeof external.CETerm != 'undefined') external.CETerm.PostIDA( "IDA_BEEP", 0 );
</script>
BGSOUND:
<bgsound src="/sap/public/bc/its/mimes/itsmobile/99/sounds/all/sapsounderr.wav" loop="4">
Device Details:
RF Device - Intermec CK71
Wavelink Velocity Client - Release 1.0.29 - 07/01/2014
Operating System-Windows Embedded 6.5 Classic. CE OS 5.2.29217 (Build 29217.5.3.12.26)
Thanks,
ER
How to enables the Function and Enter keys under a SAP ITSMobile session executed with the Wavelink TelnetCE web browser?
Hello:
I am currently testing a Zebra WT6000 and an RS6000 ring scanner. I have set up a project within the Velocity Console (Ver. 1.2.101) and have deployed that project to the WT6000. When I scan a barcode, I need to issue and Enter key and am not sure how to do this. DataWedge is also installed on the WT6000 with a Velocity Profile and I have enabled Send ENTER key in the basic data formatting. However, when I exit the DataWedge application it does not seem to save that information.
Thank you.
I have two scenarios where I would like to be able to force an APK update to a device.
1) An updated version of an APK has been released, but the actual APK version has not been incremented.
2) An existing APK deployment has become corrupted in some way and I need to force a reinstall.
Is there any way to do this in Avalanche 6.1 SP2? I have a sinking feeling that this is not possible. I understand that Android is not going to allow a direct installation of the exact same APK package name and version on a device, but I don't understand why the Enabler, as a Device Administrator, can't first uninstall the application and then reinstall it. Avalanche supports a "Force Package Synchronization" functionality for the legacy WinMo/CE devices so I'm surprised their isn't anything comparable for Android devices.
Hello,
we are experiencing problem with VelocityCE running on Datalogic Falcon X3+.
We installed appropriate client from Wavelink download page.
We also installed VelocityCE server on Xeon machine with Windows 2012 server OS.
Device reaches velocity server but nothing is displayed, after some time there's "Reconnecting" on the client.
We checked log on the server and it looks like that there's some problem with java script on the page.
That web page loads normally on IE or Chrome, from the machine where Velocity server is installed.
When we tested few months ago it worked without problem, so we can't figure out what is going on...
VelocityCE server log is in attachment.
Best regards, Nikola Nikolic
Got today the new MC9200.
Speaker ist terrible loud, so i set via control Panel the volume to Soft. After cold boot, the Sound ist set again to Default.
How can i prevent this. Windows Embedded Compact is new to us.
Thx
Ralf
Anyone know how I can do this? When I Start TelnetCE a windows comes up
"Scanner Selection" Do you want to use the scanner "Bluetooth SSI Scanner Driver" instead of the Default scanner "External SSI"
I have to hit no to continue with the connection Profile.
Running TelnetCE version 7.3.158
Thanks,
Hi there,
We are using a Zebra VC70 with customer's web application, if I press CTRL and + it zooms in nicely. Repeating this 5 times puts the application at the perfect scale size on screen.(large)
However when we move to the next page the scale is back to original (small)
Ideally we want this large "zoom level" to apply to all pages.
How can we emulate this with WIB?
I have also tried inserting CSS however no zoom/scale seems to work as well as this method.
Regards,
Erron
I am using a CK71 with Wavelink client to access customer's SAP ITS web, but i can not adjust size of SAP ITS in Wavelink client. i attach my Wavelink config file and put a screenshot for reference.
Here is my device version: CK71 with OS 1.50 Chinese,
Wavelink client:WLTE_ITC_CK71_WM6_LANG_7_3_237_AS.exe.
Any solution for that?
Thanks,
Hi all
i need to use DATALOGIC FALCON X3 connected to an As400 via 5250 emulator .. i don't understand how to configure keyboard key (not virtual keyboard) so that i can emulate "ENTER" and "Exit fields" keys tipical for As400
Thanks in advance
How can I disable the scan function on ONE FIELD only on a screen? How can I include it on my current script?
//Let's create a function to process the scan
function onScan(event)
{
//Well just handle the scan data ourselves instead of letting the default mechanism handle it
Device.sendKeys(event.data);
Device.sendKeys("{hex:000D}1{pause:500}{hex:000A}");
}
//Register the onScan function to be called when a scan occurs. Without this it will never run.
WLEvent.on("Scan", onScan);
Please, for the love of all that is good, can someone please help me with this? I am not a programmer...
Thanks!
Monica
I understand that the licenses are added through the web console (6.x) and are visible in the same area, but where are they actually being stored? I am curious to know, based on a DR planning effort.
Hi i'm having difficulties using function keys with Motorola WT41N0 Telnet CE 7.3.192 and VT200 emulation. Random charachtes or error message key not recognized is diplayed if i'm trying to use Function keys (F1; F2 etc.) Any ideas?
Hello,
on MC3190 when we use Telnet CE ( any version) the level of the sound is not enough loud to be hear by a end user in the warehouse
we need to know how we can set correctly TelnetCE to have a very heavy sound
thanks
Sebastien
I am trying to remotely do this using Avalanche without having to go to 150 scanners and do this individually :
1. Start > Settings > System > Intermec Settings > Device Settings > Power Management > Battery Power > Device turns off after > Disabled.
2. Start > Settings > System > Intermec Settings > Communications > 802.11 Radio > Funk Security > Profile 1 > Power Mode – Change this from PSP to CAM. CAM is Constant Awake Mode and is typically intended for devices where power isn’t an issue and usually provides better connectivity performance.
Anyone know if there is a setting that will allow me to deploy this with a few clicks?